Install Range Hood; Connect Vent System - Whirlpool WVW57UC6FS Installation Instructions And Use & Care Manual

Wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Install Range Hood

NOTE: Remove protective film from range hood and metal filters.
1. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A
B
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2. Remove the grease filter. See "Range Hood Care" section.
3. Level the range hood and tighten upper mounting screws.
4. Install (2) 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.

Connect Vent System

1. Install transition on top of hood (if removed for shipping)
with (2) 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
1. Fit vent system over the exhaust outlet.
2. Seal connection with clamps.
3. Check that backdraft dampers work properly.
8
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the duct cover bracket with
4 assembly screws provided with the Recirculation Kit.
C
A. Assembly screws
B. Air deflector
C. Duct cover bracket
2. Measure from the bottom of the air deflector to the bottom
of the hood outlet.
B
D
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
3. Cut the duct to the measured size "X."
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over
the exhaust outlet from the hood.
7. Reassemble the air deflector to the duct cover
bracket with the 4 assembly screws.
8. Seal connections with vent clamps.
A
B
A
C
X

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wvw57uc0fs

Table of Contents