Component Testing Procedures
To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
Illustration
Electronic Control
Keyboard assembly
RFS18TS
16500024
!
WARNING
Component
Continuity is indicated as
100
1
2
3
4
5
6
7
8
9
10
11
Testing
Pad
and below.
0
1
2
3
4
5
6
7
8
9
HOLD (0%)
DEFROST (20%)
MEDIUM (50%)
MED-HI (70%)
TIME ENTRY
STOP/RESET
START
4
Results
Trace
Measurement
1 & 8
Continuity
2 & 8
Continuity
3 & 8
Continuity
4 & 8
Continuity
5 & 8
Continuity
6 & 8
Continuity
7 & 8
Continuity
1 & 9
Continuity
2 & 9
Continuity
3 & 8
Continuity
1 & 10
Continuity
2 & 10
Continuity
3 & 10
Continuity
4 & 10
Continuity
5 & 10
Continuity
6 & 10
Continuity
7 & 10
Continuity