6  Electrical Connection
8. Ensure that the grounding cable of the module is
connected to the ground connection in the inverter.
9. Secure the conduit fitting from the inside using the counter nut.
10. Connect the insulated conductors that are connected to the three-colored terminals of the SPS
module to the outlet.
11. Connect the insulated conductors that are connected to the black terminals of the SPS module
to the switch.
12. Attach the supplied warning label to the secure
power outlet.
13. Label the switch using the supplied label. Label the
closed switch position with "ON" and the opened
switch position with "OFF".
Information on the use of the outlet
You will find further information on the use of the outlet and on the connection conditions in the
user manual supplied. Please inform the PV system operator.