Performance Data Sheet - Pentair OMNIFILTER OM34K Installation Instructions Manual

Water softening system
Table of Contents

Advertisement

Available languages

Available languages

PERFORMANCE DATA SHEET

Model
Maximum Rated Service Flow (gpm)
(W/upper collector)
Pressure Drop at Rated Service Flow Rate (gpm)
Rated Capacity (grains @ lbs . of salt)
Rated Efficiency (grains/lb. Salt @ lbs. of salt)
Maximum Flow Rate During Regeneration (gpm)
Resin Volume per tank - ft
3
- Strong Acid cation
Tank size
Operating Pressure:20 -125 psi or 1.4 – 8.8 kg/Centimeter
Acceptable Salt Type: Sodium Chloride
All Systems above tested at 35psi +/- 5 psi, pH of 7.5 +/- 0.5,
Capacity Testing Flow Rate = 50% of the rated service flow rate for the various size systems.
These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specific
performance claims as verified and substantiated by test data. The rated salt efficiencies above were
also determined in accordance with NSF/ANSI 44 and are only valid at the salt dosage referenced
above. An efficiency rated water softener is a demand initiated regeneration (DIR) softener which also
complies with specific performance specifications intended to minimize the amount of regenerant brine
and water used in its operation. Efficiency rated water softeners shall have a rated salt efficiency of not
less that 3350 grains of total hardness exchanged per pound of salt (based on NaCl equivalency) (477
grams of total hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed
rating. The rated efficiency of the water softener, the salt dosage at that efficiency, the capacity at that
salt dosage and that of the efficiency is only valid at the stated salt dosage. Efficiency is measured
by a laboratory test described in NSF/ANSI 44. The test represents the maximum possible efficiency
the system can achieve. Operational efficiency is the actual efficiency achieved after the system has
been installed. It is typically less than the efficiency due to individual application factors including water
hardness, water usage, and other contaminants that reduce the water softener's capacity . These
systems are not intended to be used for treating water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system . Refer to the system Installation and
Service Manals for set-up and programming instructions .
Contact your local dealer for parts and service . See your owner's manual for warranty information .
Iowa Requirement:
Seller: ________________________________________________ Date:_________________________
Buyer: ________________________________________________ Date:________________________
20 •
ResinType
13845 Bishops Dr., Suite 200
Brookfield, WI 53005
PH: (800) 279-9404
OM34K
9 .6
15
15,095 @ 3 .4
34,433 @ 16 .7
4,400 @ 3 .4 lbs .
2 .1
1 .04 ft
per tank
3
9" x 48"
, Operating Temperature: 34 - 110° F or 1 .1 – 43 .3° C
2
OMNIFILTER
OM40K
10 .7
14
18,143 @ 4 .12
41,386 @ 20 .0
4,400 @ 4 .1 lbs .
2 .7
1 .25 ft
per tank
3
10" x 44"
Tested and Certified
by WQA to NSF/
ANSI Standard 44
& 372 for softener
performance & lead
free compliance and
CSA B483 .1 .

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omnifilter om40k

Table of Contents