Performance Data Sheet - Pentair OMNIFILTER OM26K Manual

Table of Contents

Advertisement

Available languages

Available languages

PERFORMANCE DATA SHEET

Model
Maximum Rated Service
Flow (gpm) (W/upper
collector)
Pressure Drop at Rated
Service Flow Rate (gpm)
Rated Capacity
(grains @ lbs of salt)
Rated Efficiency
(grains/lb Salt @ lb of salt)
Maximum Flow Rate During
Regeneration (gpm)
Resin Volume per tank - ft
3
Resin Type - Strong Acid
Cation
Tank size
Operating Pressure:20 -125 psi or 1.4 – 8.8 kg/Centimeter
Acceptable Salt Type: Sodium Chloride
All Systems above tested at 35psi +/- 5 psi, pH of 7.5 +/- 0.5,
Capacity Testing Flow Rate = 50% of the rated service flow rate for the various size systems.
These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specific
performance claims as verified and substantiated by test data. The rated salt efficiencies above were also
determined in accordance with NSF/ANSI 44 and are only valid at the salt dosage referenced above. An
efficiency rated water softener is a demand initiated regeneration (DIR) softener which also complies with
specific performance specifications intended to minimize the amount of regenerant brine and water used
in its operation. Efficiency rated water softeners shall have a rated salt efficiency of not less that 3350
grains of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of total
hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed rating . The rated
efficiency of the water softener, the salt dosage at that efficiency, the capacity at that salt dosage and
that of the efficiency is only valid at the stated salt dosage. Efficiency is measured by a laboratory test
described in NSF/ANSI 44. The test represents the maximum possible efficiency the system can achieve.
Operational efficiency is the actual efficiency achieved after the system has been installed. It is typically
less than the efficiency due to individual application factors including water hardness, water usage, and
other contaminants that reduce the water softener's capacity . These systems are not intended to be used
for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system . Refer to the system Installation and Service Manals for set-up and programming
instructions .
Contact your local dealer for parts and service . See your owner's manual for warranty information .
Important Notice: For conditions of use, health claims certified by the California Department of Public
Health and replacement parts, see product data sheet
Iowa Requirement:
Seller: ________________________________________________ Date: _________________________
Buyer: ________________________________________________ Date: _________________________
OM26K
8
14
11,902 @ 2 .7
27,149 @ 13 .1
4,400 @ 2 .7 lbs
1 .7
0 .82 ft
per tank
3
8" x 44"
OMNIFILTER
13845 Bishops Dr., Suite 200
Brookfield, WI 53005
PH: (800) 279-9404
, Operating Temperature: 34 - 110° F or 1 .1 – 43 .3° C
2
Tested and Certified
by WQA to NSF/ANSI
Standard 44 & 372 for
softener performance
& lead free compliance
and CSA B483 .1 .
OM26K • 19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents