2.2 Capacity Curve in Different Outdoor Temperature

Cooling
11 0
10 0
90
80
70
60
50
40
32 33 34 35 36 37 38 39 40 41 42 43 44 45
Outdoor temp.(°C)

2.3 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(°C) (DB/WB)
Indoor
Outdoor
27/19
35/24
Heating:
Rated heating
condition(°C) (DB/WB)
Indoor
Outdoor
20/-
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Technical Information
Conditio n Cooling
Indoor:DB27°C WB19°C
Indoor air flow: Super High
Pipe length:5m
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
12K
0.9~1.1
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
12K
2.2~2.5
Heating
120
100
80
60
40
Condition Heating
Indoor:DB20°C
20
Indoor air flow: Super High
Pipe length:5m
0
-10
-7
-5
0
2
Outdoor temp.(°C)
Inlet and outlet pipe temperature
of heat exchanger
T1 (°C)
T2 (°C)
in:8~11
in:75~85
out:11~14
out:37~43
Inlet and outlet pipe temperature
of heat exchanger
T1 (°C)
T2 (°C)
in:75~85
in:1~3
out:37~43
out:2~5
10
15
24
5
7
Fan speed of
Fan speed of
indoor unit
outdoor unit
Super High
High
Fan speed of
Fan speed of
indoor unit
outdoor unit
Super High
High
9