Led Display Detail - Mitsubishi Electric PAC-IF012B Technical Manual

Air to water (atw) heat pump, interface (i/f) and flow temp. controller (ftc)
Table of Contents

Advertisement

8. LED Display detail

Setting SW3 allows to switch the LED display.
LED1 : Power supply
LED2~4 : Setting SW3 switches the display
SW3-1
SW3-2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
[Display detail A]
LED
Details of LED display
LED2
Power supply for remote controller
LED3
Communication link between interface and outdoor units
LED4
LED5
[Display detail B]
LED
Function
LED2
Thermo
LED3
Comp.
LED4
Control status
LED5
[Display detail C]
LED2
Capacity
LED3
request status
(Output)
LED4
LED5
* Displays the output status(the request which the I/F sends to the outdoor unit)
[Display detail D]
LED2
Capacity
LED3
request status
(Input)
LED4
LED5
* Displays the input state(the request which this I/F receives)
[Display detail E]
Input condition
LED
LED2
TB142 1-2(IN1)Input
LED3
TB142 3-4(IN2)Input
LED4
N/A
LED5
N/A
[Display detail F]
LED
Output condition
LED2
TB141 1-2(OUT1) Output
LED3
TB141 3-4(OUT2) Output
LED4
TB141 5-6(OUT3) Output
LED5
TB141 7-8(OUT4) Output
[Display detail G]
LED
Output condition
LED2
TB141 9-10(OUT5) Output
LED3
TB141 11-12(OUT6) Output
LED4
N/A
LED5
N/A
SW3-3
Display detail
OFF
A
OFF
B
OFF
C
OFF
D
ON
E
ON
F
ON
G
N/A
N/A
LED display and condition
OFF
OFF
ON
OFF
Normal
OFF
OFF
0% OFF
10% Fix
20% Fix
30% Fix
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
0% OFF
10% Fix
20% Fix
30% Fix
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
LED display
OFF
OFF
LED display
OFF
OFF
OFF
OFF
LED display
OFF
OFF
LED display
OFF : Power is not supplied.
OFF : No link
ON
ON
OFF
Hot adjust
Defrosting
ON
40% Fix
50% Fix
60% Fix
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
40% Fix
50% Fix
60% Fix
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
Forced Comp. OFF (ON:Forced Comp. OFF)
ON
Fixed operation mode (OFF=Cooling/ON=Heating)
ON
Operation output
ON
Error output
ON
Comp. output
ON
Defrost output
ON
Cooling output
ON
Heating output
34
ON
: Power is supplied.
Blink : Linked
ON
Demand
Comp. OFF
ON
70% Fix
80% Fix
90% Fix
100% Fix
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
70% Fix
80% Fix
90% Fix
100% Fix
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
Details
Details
Details
Auto
OFF
ON
ON
ON
OFF
OFF
ON
ON
Auto
OFF
ON
ON
ON
OFF
OFF
ON
ON

Advertisement

Table of Contents
loading

Table of Contents