Mitsubishi Electric PAC-IF012B Technical Manual page 25

Air to water (atw) heat pump, interface (i/f) and flow temp. controller (ftc)
Table of Contents

Advertisement

Note:
• REMOTE SWITCH Type A (4bit - 8 setting) / Type B (1bit -1 setting)
TB142
TB142
TB142
10-11
10-12
10-13
(COM-IN5)
(COM-IN6)
(COM-IN7)
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
* The actual capacity will be slightly different from the numeral data in this table depending on conditions such as the ambient
temperature.
Interface controller
Attachment of sensor
switch setting
Refer to 4.
2 patterns can be
set.
(Refer to NOTE 1.)
Pipe-thermistor/
2-phase might be
Type A
neccessary
SW1-1:OFF
depending on the
SW1-2:OFF
type of the outdoor
SW1-3:OFF
unit.
SW6-1:OFF
SW6-2:OFF
Type B
Refer to 4.
SW1-1:ON
SW1-2:OFF
Pipe-thermistor/
SW1-3:OFF
2-phase might be
SW6-1:OFF
neccessary
SW6-2:OFF
depending on the
Other switches are
type of the outdoor
to be set according
unit.
to the site.
Refer to 5 for details.
SW1-1:OFF
Refer to 4.
SW1-2:ON
SW1-3:ON
Pipe-thermistor/
SW6-1:OFF
2-phase might be
SW6-2:OFF
neccessary
depending on the
Other switches are
type of the outdoor
to be set according
unit.
to the site.
Refer to 5 for details.
Refer to 4.
Pipe-thermistor/
2-phase might be
neccessary
depending on the
type of the outdoor
unit.
Refer to 4.
SW1-1:OFF
Pipe-thermistor/
SW1-2:OFF
2 - p h a s e m i g h t b e
SW1-3:ON
neccessary depending
o n t h e t y p e o f t h e
SW6-1:OFF
outdoor unit.
SW6-2:OFF
Refer to 4.
Other switches are
Pipe-thermistor/
to be set according
2 - p h a s e m i g h t b e
to the site.
neccessary depending
o n t h e t y p e o f t h e
Refer to 5 for details.
outdoor unit.
Step for capacity setting *
TB142
10-14
TypeA
(COM-IN8)
OFF
[OFF]
OFF
0%
OFF
[ON]
Step1
10%
OFF
Step2
20%
OFF
Step3
30%
OFF
Step4
50%
OFF
Step5
70%
OFF
Step6
80%
OFF
Step7
100%
ON
Auto step
Interface controller specifications
Input and wiring
Type A
OFF/Step1/Step2/
···Step7/Auto step
Type B
OFF/Step1/Step4/
Step7/Auto step
Refer to 6 for details.
TB62
Connect the wired
remote
controller wire to
No.5-6
Wiring
Wire NO.×size(mm
2×0.3(Non-polar)
Max. 500m
Circuit rating
DC12V
The figure is NOT
always against the
ground.
Only the operation
with remote
controller is valid.
(External signal is
invalid)
Refer to 6.
Refer to 6.
Remark
TypeB
[OFF]
OFF
0%
OFF
[ON]
Step1
10%
Step4
50%
Fixed capacity
(Hz fixed)
Step7
100%
mode
Auto step mode
Auto step
Other functions/setting
Output and wiring
Refer to 7.
Refer to 7.
Refer to 7.
)
2
Refer to 7.
Refer to 7.
Refer to 7.
25
Type A
At site
I/F
{
10
11
4 bit 8 switch
12
OFF~AUTO
13
step
14
TB142
Connection with
Maintenance
BMS/MELANS
Refer to 8, 9.
Not available
Refer to 8, 9.
Not available
Refer to 8, 9.
Available
Refer to 10.
Connect adaptor to
outdoor unit.
M-NET converter
PAC-SF80MA-E
A-Control sub
Interface
PAC-SK82SI-E
Refer to 8, 9.
Available
Refer to 10.
Connect adaptor to
outdoor unit.
M-NET converter
PAC-SF80MA-E
A-Control sub
Interface
PAC-SK82SI-E
Refer to 8, 9.
Not available
Refer to 8, 9.
Not available
Type B
At site
I/F
10
Step1
11
12
Step4
13
Step7
14
AUTO
step
TB142