Problem Solving; Mesures De Précaution - Fantom FM310K Owner's Manual

Table of Contents

Advertisement

OPERATING INSTRUCTIONS
Changing the Headlight Bulb
WARNING: To reduce the risk of
electric shock, the power cord
must be disconnected before removing
the dust cup, HEPA filter,changing the
filters or performing maintenance/trouble
shooting checks.
1. Turn unit "Off" and unplug from wall
outlet.
2. With a flat head screw driver, snap off
the lens cover by pressing down on the
two notches on the lens cover. (Fig. 29)
3. Lift off the head light lens.
4. Remove the light bulb by pulling it out
carefully.

PROBLEM SOLVING

This appliance was inspected thoroughly and was in good operating condition when it
was shipped from the factory. If a minor problem occurs, it usually can be solved quite
easily when the cause is found. Therefore, this checklist is provided for your
convenience.
PROBLEM
POSSIBLE CAUSE
1.
Not properly plugged into
wall outlet.
Cleaner Won't
2.
No electricity in wall outlet.
3.
On/Off switch not turned on.
Run
4.
Motor thermostat tripped.
5.
Blown fuse/tripped breaker.
1.
Full or clogged dust cup.
2.
Wrong pile height setting.
3.
Clogged nozzle.
4.
Clogged dust inlet port.
5.
Clogged hose.
6.
Broken belt.
Cleaner Won't
7.
Hose not inserted fully.
Pick Up
8.
Dirty filters.
9.
HEPA filter needs cleaning
or replacing.
10. HEPA filter frame needs
cleaning.
11. Blockage in unit.
Cleaner Picks
Up Moveable
1.
Wrong pile height setting.
Rugs Or Pushes
Too Hard
Agitator Does
1.
Broken belt.
Not Turn
2.
Belt installed incorrectly.
1.
Attachment use restricts air
Air Flow
flow.
Restricted With
2.
New carpet debris clogging
Attachment Use
air path.
Notches
Fig. 29
5. Replace the new bulb by pushing
it in.
6. Replace the head light lens by
pushing it in so that it snaps back in
place.
POSSIBLE SOLUTIONS
1.
Plug in firmly.
2.
Check fuse or breaker.
3.
Push on/off switch to on
4.
Reset motor thermostat.
5.
Reset circuit breaker or replace fuse.
1.
Clean dust cup.
2.
Adjust setting.
3.
Remove obstruction.
4.
Remove power head cover and
remove obstruction.
5.
Remove obstruction.
6.
Replace belt.
7.
Push hose in securely.
8.
Clean / change filters.
9.
Clean or replace HEPA filter.
10. Clean HEPA filter frame.
11. Check unit for blockages.
1.
Adjust setting.
1.
Replace belt.
2.
Check belt changing and agitator
cleaning.
1.
Check attachment.
2.
Remove obstruction.
10
MESURES DE PRÉCAUTION
IMPORTANT:
Si la trappe de succion ou le boyau se BLOQUENT, éteignez
l'aspirateur et retirez l'obstacle avant de redémarrer l'appareil.
1.
N'approchez pas l'aspirateur
trop près des éléments
chauffants ou des radiateurs.
2. Avant d'insérer la fiche d'alimentation
dans la prise murale, assurez-vous
que vos mains sont sèches.
3. Avant de commencer à nettoyer,
assurez-vous de retirer tout gros objet
ou tout objet coupant pouvant l'écran
de filtrage de la coupelle.
4.
Tenez toutes les parties du corps,
les doigts, les cheveux et les
vêtements lâches éloignés des
ouvertures, du batteur rotatif et des
autres pièces mobiles.
5.
Lorsque vous retirez le cordon
d'alimentation de la prise
murale, tirez sur la fiche et non
pas sur le cordon.
6.
Ne ramassez aucun objet fumant
ou brûlant tels que les cigarettes,
allumettes ou cendres chaudes.
7.
Évitez de faire passer l'aspirateur
sur le cordon d'alimentation.
8.
N'utilisez pas l'aspirateur sans
sa coupelle ou tous ses filtres.
27

Advertisement

Table of Contents
loading

Table of Contents