Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS
"SSCX" AND "SSCXS" SERIES
Model
HP
Number
1/2
SS1XN-
1
2
3/4
SS1XN-
3
4
3/4
SS1XS-
3
4
1
SS1XN-1
1
SS1XS-1
1-1/2
SS1XN-1
1
1-1/2
SS1XS-1
1
2
SS1
1
XN-2
4
2
SS1XS-2
2-1/2
SS1
1
XN-2
4
2-1/2
SS1XS-2
1
* 230 Volt only.
Berkeley Pumps / 293 Wright Street / Delavan, WI 53115
© 2010
OWNER'S MANUAL
REPAIR PARTS LIST
CENTRIFUGAL PUMP
High Head
ODP MOTORS
115/230/60/1
208-230/460/60/3
B78635
B78637
B82411
B78639
B82415
B78641
2
B82419
2
B78643*
B82423*
1
B78645*
2
B82427*
2
MODELS
115/230/60/1
B78636
B78638
B82412
B78640
B82416
B78642
B82420
B78644
B78655*
B82424
B82425*
B78646
B78657*
B82428
B82429*
TEFC MOTORS
208-230/460/60/3
B78647
B78648
B78649
B78650
B82413
B82414
B78651
B78652
B82417
B82418
B78653
B78654
B82421
B82422
B78656
B82426
B78658
B82430
BE495 (Rev. 10/6/10)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSCX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Berkeley SSCX Series

  • Page 1 B78656 SS1XS-2 B82423* B82424 B82425* B82426 2-1/2 ⁄ XN-2 ⁄ B78645* B78646 B78657* B78658 2-1/2 SS1XS-2 ⁄ B82427* B82428 B82429* B82430 * 230 Volt only. Berkeley Pumps / 293 Wright Street / Delavan, WI 53115 BE495 (Rev. 10/6/10) © 2010...
  • Page 2 Recommended pump suction Support discharge pipe as required and discharge connections Gate Valve Priming Plug Union Street Elbow Discharge to service Vent Plug Short length of straight pipe after reducer Important: All connections must be air tight Support suction pipe Eccentric as required Reducer...
  • Page 3: Piping - General

    PIPING - GENERAL DISCHARGE PIPING Support both suction and discharge piping independently at a Increase pipe size from pump tapping as show in Table I. Figure point near the pump to avoid putting a strain on the pump hous- 1 (Page 2) depicts a recommended run of pipe and fittings for ing.
  • Page 4 TABLE II - RECOMMENDED FUSING AND WIRING DATA - 60/50 CYCLE MOTORS DISTANCE IN FEET FROM MOTOR TO METER BRANCH 0’ 101’ 201’ 301’ 401’ MOTOR MAX. LOAD FUSE* MODEL VOLTAGE AMPERES RATING 100’ 200’ 300’ 400’ 500’ AMPS WIRE SIZE SINGLE PHASE - ODP MOTORS SS1XN- ⁄...
  • Page 5 ELECTRICAL Connection diagram for dual voltage, single-phase motors. Hazardous voltage. Can shock, burn, or Your dual-voltage motor’s terminal board (under the motor cause death. Disconnect power to motor before working on pump end cover) will match one of the diagrams below. Follow or motor.
  • Page 6: Pump Service

    SERVICE PUMP SERVICE 2. Turn seal plate over so seal cavity is up, clean cavity thoroughly. This centrifugal pump requires little or no service other than rea- 3. Lubricate outside rubber surface of ceramic seat with soapy sonable care and periodic cleaning. Occasionally, however, a water and press firmly into seal cavity with finger pressure.
  • Page 7 TROUBLE - CAUSES AND REMEDY TROUBLE AND CAUSE REMEDY FAILURE TO PUMP 1. Pump not properly primed. 1. Make sure pump casing and suction line are full of water. See priming instructions. REDUCED CAPACITY AND/OR HEAD 1. Air pockets or leaks in suction line. 1.
  • Page 12: Limited Warranty

    Your only remedy, and BERKELEY’s only duty, is that BERKELEY repair or replace defective products (at BERKELEY’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered.

Table of Contents