Fantech VER100 Installation Manual

Fantech VER100 Installation Manual

Energy recovery ventilator

Advertisement

Quick Links

VER100
Energy Recovery Ventilator
Your ventilation system should be installed in conformance with the appropriate provincial/state requirements or, in the
absence of such requirements, with the current edition of the National Building Code, and / or ASHRAE's "Good Engineering
Practices".
United States
10048 Industrial Blvd., Lenexa, KS, 66215
Tel.: 800.747.1762 • Fax: 800.487.9915
Canada
50 Kanalflakt Way, Bouctouche, NB, E4S 3M5
Tel.: 800.565.3548 • Fax: 877.747.8116
Fantech reserves the right to modify, at any time and without notice, any or all of its products' features, designs,
components and specifications to maintain their technological leadership position.
Please visit our website www.fantech.net for more detailed technical information.
Installation Manual
Item #: 427926
Rev Date: 2018-06-06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VER100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fantech VER100

  • Page 1 50 Kanalflakt Way, Bouctouche, NB, E4S 3M5 Tel.: 800.565.3548 • Fax: 877.747.8116 Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position.
  • Page 2: Table Of Contents

    Your ventilation system should be installed in accordance with the local building code that is in effect, in absence of such requirements, it is recommenced to check with local authorities having jurisdiction in your area prior to installing this product fantech fantech...
  • Page 3: Determining Your Airflow Requirement

    Bathroom: If the ERV is going to provide the required local exhaust ventilation for each bathroom with each a continuous 20 CFM (10 L/s), this ventilation rate can be considered as part of the whole-building ventilation rate. fantech fantech...
  • Page 4: Partially Dedicated System

    “Normal” speed and furnace blower is running. Fantech energy recovery ventilators (ERV) that use a supply fan shutdown for frost Fantech energy recovery ventilators (ERV) that use a supply fan shutdown for frost prevention do not include an outdoor air motorized damper. If you are using a simplified prevention do not include an outdoor air motorized damper.
  • Page 5: Option 1

    * Unit air flow should be balanced while ERV is on "Normal" speed and outside furnace blower is running. Fantech energy recovery ventilators (ERV) that use a supply fan shutdown for frost 1 Using the duct connection of 2 Pull the insulated flexible duct prevention do not include an outdoor air motorized damper.
  • Page 6: Interior Ducting Installation

    The Air return ducts, or openings for air return, should not be placed in enclosed spaces containing combustion and tighten. spring will then support the appliances that are subject to spillage. unit's weight and absorb vibrations. fantech fantech...
  • Page 7: Airflow Adjustment & Balancing

    The integrated dampers are preset at the fully opened position. In order to reduce the amount of airflow, turn the adjustable lever using a flat screw driver by turning it counter clock wise. Turning the lever clockwise may damage the plastic screw head. Follow the balancing steps to properly adjust the airflow. fantech fantech...
  • Page 8: Balancing Steps

    • Up to 5 can be used in one system • Use in bathroom, kitchen, laundry room MDEH1 • Rotary dial Dehumidistat • Multiple units can be used • We recommend setting the relative humidity above 80% during the summer Illustration #2 Illustration #3 fantech fantech...
  • Page 9: Wiring Diagram

    TERMINAL BLOCK COOLING SYSTEM WIRE As per building codes and installation requirements for combustion appliances: Air return ducts, or openings for air return, should not be placed in enclosed spaces containing combustion appliances that are subject to spillage. fantech fantech...
  • Page 10: Troubleshooting

    20 gallons of water. Vacuum the Inside of the Annually • The fans found in all Fantech ERVs Dryer vent exhaust is inside home Make sure the dryer vent is exhausting outside. Unit...
  • Page 11: Erv Core Washing Instructions

    Collar 5”, Oval, w/Stop 412826 Collar 5”, Oval, wo/Stop 412827 Screw, Set, Slotted, 8-32 x 5/16” 412836 Cap, w/Tab, Plastic, Tapered 412839 Damper, 5”, Oval 412831 Temperature Probe 40286 Door Assembly 426619 Kit, Wall Bracket 409720 Kit, Chain 404261 fantech fantech...
  • Page 12 Notes Notes fantech fantech...
  • Page 13 Fantech reserves the right to make technical changes. Fantech se réserve le droit de faire des changements tech- For updated documentation please refer to www.fantech.net niques. Pour de la documentation à jour, s'il vous plaît se référer au www.fantech.net Fantech®...