BEKA BA648CF-P Manual

BEKA BA648CF-P Manual

Profibus pa panel mounting 8 variable fieldbus indicator

Advertisement

Quick Links

BA648CF-P
PROFIBUS PA
Panel mounting
8 variable
Fieldbus Indicator
Issue: 2
Issue 2
rd
23
June 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BA648CF-P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BEKA BA648CF-P

  • Page 1 BA648CF-P PROFIBUS PA Panel mounting 8 variable Fieldbus Indicator Issue: 2 Issue 2 June 2011...
  • Page 2: Table Of Contents

    CONTENTS 1. Description 6. Maintenance 1.1 Documentation 6.1 Fault finding during commissioning 6.2 Fault finding after commissioning 2.Operation 6.3 Servicing 2.1 Error messages 6.4 Routine maintenance 6.5 Guarantee 3. System Design for Hazardous Area 6.6 Customer comments 4. Installation 4.1 Location 7.
  • Page 3: Description

    No data is being received When configured as a fieldbus listener, the with the current configuration. BA648CF-P is not visible to the fieldbus host and can only be configured using the push buttons on the front of the instrument. 3. SYSTEM DESIGN...
  • Page 4: Installation

    4. INSTALLATION 4.2 Installation Procedure 4.1 Location a. Insert the BA648CF-P into the instrument The BA648CF-P is housed in a robust aluminium panel cut-out from the front of the panel. enclosure with a toughened glass window mounted in a Noryl bezel.
  • Page 5: Configuration

    5.2.2 Access code for configuration menu ‘CodE’ As a fieldbus listener, the BA648CF-P is not visible Access to the node configuration menu may be to the fieldbus host and can only be configured via protected by a four digit security code which must the front panel push buttons using the menu be entered to gain access.
  • Page 6: Listener Configuration Menu

    Please refer to the quick set-up procedure in the 5.3 Listener configuration menu BEKA PROFIBUS PA Display – Fieldbus Interface When used as a fieldbus listener the BA648CF-P Guide. is not visible to the fieldbus host and can only be configured using the front panel push buttons 5.2.4 Reset the instrument to node factory...
  • Page 8: Access

    'SCAn’ will be displayed. entered. If the BA648CF-P is protected by an access code, See section 5.4.5 ‘CodE’ will be displayed first. Pressing P will allow the four digit security code to be entered digit by ‘dSt’...
  • Page 9: Description Of Listener Menu Functions

    If one of the eight BA648CF-P Listener’s inputs in- as shown in Fig 5. If there is more than one data 1 to in-8 has not had a Source Address, source, operating the ▼...
  • Page 10: Enter Source Address

    Address to be entered and allocated to the function press P which will reveal the existing BA648CF-P listener input selected in the Edit setting. The display may be changed using the ▼ function. The data location is manufacturer specific or ▲...
  • Page 11: Configuration Menu

    ‘oFFSt’ prompt in the sub-menu. Three operations of the E button will return to the The BA648CF-P listener may be reset to the ‘Edit’ function in the main configuration menu. factory defaults that are shown below:...
  • Page 12: Maintenance

    6.2 Fault finding after commissioning ENSURE PLANT SAFETY BEFORE STARTING MAINTENANCE If a BA648CF-P fails after it has been functioning correctly, the table shown in section 6.1 may help to identify the cause of the failure. If this procedure does not reveal the cause of the fault, it is recommended that the instrument is replaced.
  • Page 13: Accessories

    7.2 Tag number The BA648CF-P can be supplied with a thermally printed tag number on the rear panel adjacent to the terminals. 7.3 BEKA PROFIBUS PA Display – Fieldbus Interface Guide.