Product Description; Regulations; Transport; Installation - Buderus SM400/5E Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

3

Regulations

Continuous output (at 80 °C flow temperature, 45 °C DHW outlet temperature and 10 °C cold water
temperature)
Heat-up time at rated output
5)
Maximum heat input
Maximum heating water temperature
Max. heating water operating pressure
Connection size, heating water
Pressure loss diagram
Table 4 Dimensions and specification (
1) Without solar heating or reheating; selected cylinder temperature 60 °C
2) Mixed water at the draw-off point (at 10 °C cold water temperature)
3) Distribution losses outside the buffer cylinder are not taken into account.
4) The performance factor NL=1 to DIN 4708 for 3.5 occupants, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, outlet 45 °C and cold water 10 °C. Measured
at max. heat input. The N
drops with reduced heat input.
L
5) Limit to the stated value for heat sources with higher heat input.
2.5

Product description

Pos. Description
1
DHW outlet
2
Cylinder flow
3
Sensor well for temperature sensor, heat source
4
DHW circulation connection
5
Cylinder return
6
Cold water inlet
7
Inspection apertures for service and cleaning at the front
8
Indirect coil for reheating by the boiler, enamelled smooth tube
9
Cylinder, enamelled steel
10
Fitted magnesium anode without electrical insulation
11
PS casing lid
12
Casing, painted sheet metal with rigid polyurethane foam
insulation, 50 mm
Table 5 Product description (
page 108)
3
Regulations
Observe the following directives and standards:
• Local regulations
• EnEG (in Germany)
• EnEV (in Germany)
Installation of, and equipment for, heating and water heating systems:
• DIN and EN standards
– DIN 4753-1 – Water heaters ...; requirements, identification,
equipment and testing
– DIN 4753-3 – Water heaters ...; corrosion protection on the
water side through enamel coating; requirements and testing
(product standard)
– DIN 4753-6 – Water heating systems ...; cathodic corrosion
protection for enamelled steel cylinders; requirements and
testing (product standard)
– DIN 4753-8 – Water heaters ..., part 8: Thermal insulation of
DHW cylinders up to 1000 l nominal capacity – requirements and
testing (product standard)
– DIN EN 12897 – Water supply - regulation for... DHW cylinders
(product standard)
– DIN 1988 – Technical rules for potable water installations
– DIN EN 1717 – Protection of potable water against
contamination...
22
Fig. 1, page 104 and Fig. 3, page 105)
Fig. 3, page 105 and Fig. 11,
Unit
kW
l/min
min
kW
°C
bar (positive)
DN
– DIN EN 806 – Technical rules for potable water installations
– DIN 4708 – Central DHW heating systems
• DVGW
– Code of practice W 551 – Potable water heating systems and
pipework; technical measures to inhibit the growth of legionella
bacteria in new systems;...
– Code of Practice W 553 – Sizing DHW circulation systems... .
4

Transport

▶ When handling, prevent DHW cylinders from falling.
▶ Move packed DHW cylinder with a sack trolley and strap ( Fig. 4,
page 106).
-or-
▶ Move unpacked DHW cylinder with a transport net; during handling,
protect connections against possible damage.
5

Installation

The DHW cylinder is delivered as a fully assembled unit.
▶ Check that the DHW cylinder is complete and undamaged.
5.1

Siting

5.1.1

Installation site requirements

NOTICE: System damage through inadequate load
bearing capacity of the supporting surface or unsuitable
substrate.
▶ Ensure that the installation area is level and offers
sufficient load-bearing capacity.
▶ Site the DHW cylinder on a plinth if there is a risk that water may
collect at the installation site.
▶ Site the DHW cylinder in dry internal areas that are free from the risk
of frost.
▶ Observe the minimum room height ( Table 4, page 21) and
minimum wall clearances inside the installation room
( Fig. 6, page 106).
5.1.2

Positioning the DHW cylinder

▶ Stand the DHW cylinder upright and level it ( Fig. 6 to Fig. 8,
page 107).
▶ Remove protective caps ( Fig. 9, page 107).
▶ Apply Teflon tape or Teflon string ( Fig. 10, page 107).
SU300/5 | SU400/5 – 6 720 800 019 (2015/04)
SM300/5
SM400/5(E)
36,5
56
897
1376
12
19
36,5
56
160
160
16
16
R1"
R1"
 Fig.
, page
2
105

Advertisement

Table of Contents
loading

This manual is also suitable for:

Su400/5Su300/5

Table of Contents