Removal Procedure; Removal Procedure Of Indoor Unit - Gree GWC09QC-A3DNA3D Service Manual

Table of Contents

Advertisement

Service Manual

11. Removal Procedure

11.1 Removal Procedure of Indoor Unit

Take A1 panel for example
Step
1. Remove filter assembly
Open the front panel. Push the left filter
and right filter until they are separate from
the groove on the front panel.
Remove the left filter and right filter
respectively.
2. Remove horizontal louver
Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
3. Remove panel
a
(1)A1 display: Screw off the 2 screws that
are locking the display board. Separate
the display board from the front panel.
(2)A3/A5 display: Screw off the 2 screws
that are locking the display board.
b
Separate the panel rotation shaft from
the groove fixing the front panel and then
removes the front panel.
Installation and Maintenance
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
Procedure
Front panel
Left filter
Horizontal louver
A1 display
A3 display
Screws
Front panel
Right filter
Groove
Location of step motor
Axile bush
Screws
Panel rotation
Groove
Front
case
Panel
A5 display
Screws
79