CS-SA9CKP CU-SA9CKP5 / CS-SA12CKP CU-SA12CKP5
7.2.
Soft Dry Mode Operation
• • • • When selecting Soft Dry mode operation, the operation will be cooling untill the room temperature reaches the set temp on the
remote control, and then Soft Dry will be actived. (During Soft Dry Mode the fan of indoor unit will operate at super low speed.)
• • • • Once soft Dry mode operation is turned off, indoor fan, compressor and outdoor fan will stop for 6 minutes.
Time Delay Safety Protection
• • • • During cooling mode operation, if the compressor ceased, it will not restart within 3 minutes.
Anti Freezing Control
• • • • Same as the denotation in Cooling Operation. (P.14)
(During Soft Dry Mode Operation, compressor will stop for at least 6 min.)
Compressor Protection Control
• • • • Same as the denotation in Cooling Operation. (P.14)
Anti-reverse Control
• • • • Same as the denotation in Cooling Operation. (P.14)
Automatic Fan Speed
During Soft Dry Operation, use remote controller to select Auto Fan Speed mode.
• • • • Indoor Fan Speed is at super low.
• • • • Deodorization control.
16