3.3 External sensor with control function "CONTROL MODE"

The temperature of the external sensor is controlled in this operating mode. The external sensor
records the actual value (control variable) for the temperature control. The setting for the setpoint
value at the unit must therefore be adapted to the measured temperature (actual value) of the
external sensor. The actual value of the external sensor is shown in the display (1).
A basic prerequisite for faultless application is direct contact of the sensor on the assembly or
component.

4. Lock Mode

The device can be locked by inserting and removing a coded plug in socket (21). The current
soldering parameters cannot be further changed. The WHA 3000P can only be operated using the
START/STOP (10) and VAC (11) Control Keys.

5. Switching Temperature Conversion

By pressing the Control Key "Temp" (7) when switching on the unit (4), you can toggle between the
operating modes "°C" and "°F". The following appears briefly in the display (1):
°C
6. RS232 interface
Using additional software, the device can be operated completely via the RS232 interface (21).
7. Work instructions
The hot air nozzle is designed such that the vacuum plate lies flat on the component. The vacuum
plate is also used for the transfer of heat. When the vacuum is enabled, the component can be lifted
after the solder has reflowed. Here it is important to pre-heat the vacuum plate to operating
temperature prior to de-soldering. As an option, it is possible to use a vacuum cup in place of the
vacuum plate.
Nozzle change
Caution:
Risk of burns! The hot air nozzle remains hot for some time after power off or
removal.
The hot air nozzles are fastened to the heating element using a clamping screw. To change the
nozzle, loosen the screw and remove the hot gas nozzle using the Nozzle Change Tool provided.
External sensor active in "CONTROL MODE"