Genelec 8260A Operating Manual page 3

Table of Contents

Advertisement

Available languages

Available languages

Mains power
switch
GLM Control
Network
connectors
Mains input
connector
12V Remote
connector
(8260A only)
Figure 2. Connectors and controls on the back panel of a 8260A. 8240A, 8250A and 8351A share the same layout but
without the 12 V trigger voltage connector.
"DIGITAL IN AES/EBU" Connector
Use this female XLR connector for AES/EBU formatted digital
audio input signals. This input is selected automatically when
a valid digital audio signal is present, and overrides the analog
input.
Depending on the digital hardware, transmission of a 192 kHz
sample rate is achieved using a double speed, single chan-
nel/cable interface. This is called dual-wire mode. In this case
one cable per channel is used and no channel selection is
required. Dual-wire mode is automatically detected by the in-
put stage.
If the digital source device has a volume fader that controls
the digital level, it may be advantageous to lower the level
control either on the computer interface or on the monitor's
back panel controls, which in turn will force the use of more of
the digital [bit] resolution in the volume control.
If the digital inputs are used, all audio outputs are referenced
to 0 dBFS (digital Full Scale, the largest level that may be rep-
resented in the AES/EBU signal). These monitors produce 100
dB SPL at 1 meter in free space for a digital input signal of
–30 dB FS.
"DIGITAL THRU AES/EBU" Connector
This male XLR carries an unaltered copy of the digital signal
fed into the "DIGITAL IN AES/EBU" connector. It can be used
for daisy-chaining up to four monitors together.
"ANALOG IN" Connector
Use this connector for analog audio signals. The maximum
input level is +7.0 dBu RMS on models 8240A and 8250A and
-10
1
ON
OFF
-12
2
ON
OFF
SWITCH
BASS
BASS
DESKTOP
TREBLE
STORED
AES/EBU CH.
DRIVER MUTE
SYSTEM LVL.
ROLL-OFF
TILT
TILT
A
B
WF
COAX
-10
1
ON
OFF
-2 dB -4 dB
-2 dB -4 dB
-4 dB
+2 dB -4 dB
160 Hz
MANUAL
ON + ON
SUM A AND B
CTRL
OFF + OFF
-6 dB
-6 dB
-2 dB
12 V
DIGITAL IN
DIGITAL THRU
ANALOG
MAINS INPUT 230 V~
50 / 60 Hz 330 W
REMOTE
AES/EBU
AES/EBU
8260A DSP TRI-AMPLIFIED
MONITORING SYSTEM
SERIAL NUMBER
MAGNETICALLY SHIELDED
www.genelec.com
MADE IN FINLAND
+22.0 dBu RMS on models 8351A and 8260A. When A/D con-
verter input clip occurs the front panel light turns momentarily
red, indicating the overload condition.
"CONTROL NETWORK" Connectors
Use these RJ-45 sockets to connect the monitor to the propri-
etary Genelec Loudspeaker Manager™ (GLM™) network only.
This connector is not Ethernet LAN compatible. Do not con-
nect to Ethernet LAN.
"12 V REMOTE" Connector (8260A only)
You can set up remote controlled powering up and down of
the 8260A with 12 V voltage connected to this connector. The
minimum current needed to actuate this function is 70 mA.
Front Panel Warning Light
Device LED action
Steady green
Slowly blinking green
From yellow to green
Steady yellow
Flashing red
Flashing red
Flashing red
Flashing yellow
Table 1. Monitor and subwoofer front panel light indications
summary
Stand-alone user
-8
interface level control
-6
-4
-2
0
dB
Stand-alone user
SWITCH
interface switch
-20
2
-30
dB
groups 1 and 2
IN
Analog input connector
Digital Thru connector
Digital input connector
Meaning and resolution
Normal state
Normal ISS power save state
Normal operation during device start
Monitor or subwoofer is not part of the group
Signal clip (analog)
Bit errors in incoming digital AES/EBU audio
Digital signal potential clip (digital audio is very
close to 0 dB FS)
Protection