Daikin Altherma EBLQ07CAV3 Installation Manual page 15

Low temperature monobloc
Hide thumbs Also See for Altherma EBLQ07CAV3:
Table of Contents

Advertisement

#
Code
[7.7.1.2]
[1-06]
Weather-dependent curve (cooling):
T t
[1-07]
[1‑08]
[1-08]
[1-09]
[1-09]
▪ T
(main)
▪ T
Leaving water temperature: Additional zone
#
Code
[A.3.1.2.1]
N/A
Set point mode:
▪ 0 (Fixed): Absolute
▪ 1
dependent
▪ 2
scheduled (only for leaving water
temperature control)
▪ 3
dependent + scheduled (only for
leaving water temperature control)
[7.7.2.1]
[0-00]
Weather-dependent curve (heating):
T t
[0-01]
[0-02]
[0-01]
[0-03]
[0-00]
▪ T
(additional)
▪ T
[7.7.2.2]
[0-04]
Weather-dependent curve (cooling):
T t
[0-05]
[0-06]
[0-05]
[0-07]
[0-04]
▪ T
(additional)
▪ T
Leaving water temperature: Delta T source
#
Code
[A.3.1.3.1]
[9-09]
Heating: required temperature
difference between entering and
leaving water.
In case a minimum temperature
difference is required for the good
operation of the heat emitters in heating
mode.
EBLQ+EDLQ05+07CAV3
Daikin Altherma low temperature monobloc
4P403578-1F – 2018.06
Description
[1-06]
[1-07]
: Target leaving water temperature
t
: Outdoor temperature
a
Description
(Weather
dep.):
Weather-
(Fixed/scheduled):
Absolute
(WD/scheduled):
Weather-
[0-03]
[0-02]
: Target leaving water temperature
t
: Outdoor temperature
a
[0-07]
[0-06]
: Target leaving water temperature
t
: Outdoor temperature
a
Description
#
Code
[A.3.1.3.2]
[9-0A]
Leaving water temperature: Modulation
T a
#
Code
[A.3.1.1.5]
[8-05]
N/A
[8-06]
+
INFORMATION
When leaving water temperature modulation is enabled,
the weather‑dependent curve needs to be set to a higher
position than [8-06] plus the minimum leaving water
temperature setpoint required to reach a stable condition
on the comfort setpoint for the room. To increase
efficiency, modulation can lower the leaving water setpoint.
T a
By setting the weather‑dependent curve to a higher
position, it cannot drop below the minimum setpoint. Refer
to the illustration below.
T t
+[8-06]
−[8-06]
a
Weather-dependent curve
b
Minimum leaving water temperature setpoint required to
T a
reach a stable condition on the comfort setpoint for the
room.
5 Configuration
Description
Cooling: required temperature
difference between entering and
leaving water.
In case a minimum temperature
difference is required for the good
operation of the heat emitters in cooling
mode.
Description
Leaving water temperature modulation:
▪ 0 (No): Disabled
▪ 1 (Yes): Enabled. The leaving water
temperature is calculated according
to the difference between desired
and actual room temperature.
This allows better matching of the
heat  pump
capacity
to
required capacity and results in less
start/stop cycles of the heat  pump
and more economic operation.
Leaving water temperature maximum
modulation:
0°C~10°C (default: 3°C)
Requires modulation to be enabled.
This is the value by which the desired
leaving water temperature is increased
or lowered.
a
b
T a
Installation manual
actual
15

Advertisement