OPERATION
Continued
3. Set remote selector switch in the AUTO
position (see Figure 36).
4. Press in and turn control knob clock-
wise
to the OFF position (see
Figure 32).
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B"
in the safety information on page 20. If
you don't smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
Press in control knob for five (5) seconds
(see Figure 36).
Note: You may be running this heater
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the rear of the front
burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
Ignitor Button
Control Knob
Figure 36 - Remote Selector Switch,
Control Knob and Ignitor Button
121308-01E
to the PILOT position.
ON REMOTE OFF
Remote Selector
Switch
www.desatech.com
9. Slightly push in and turn control knob coun-
terclockwise
10. Press the on/off key on the remote control
to turn on appliance main burner. Wait at
least 5 seconds before setting desired
flame height.
11. Select manual flame height function by
pressing MODE button on remote until
a flame is shown in lower left corner of
display. Use the UP/DOWN arrow button
to set desired flame height (see Figure
41, page 22).
12. To leave pilot lit and shut off burners only,
turn control knob clockwise
PILOT position, or use remote control ON/
OFF button
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Pilot Burner
Figure 37 - Pilot (Propane/LP)
Pilot Burner
Figure 38 - Pilot (Natural)
TO TURN OFF GAS
1. Press on/off key on remote control and
turn control knob clockwise
OFF position (see Figure 36).
2. Close equipment shutoff valve (see Figure
22, page 16).
MANUAL LIGHTING
PRG
1. Follow steps 1 through 7 under Lighting
Instructions, page 20.
2. Depress control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 9
through 11 under Lighting Instructions.
to the ON position.
Ignitor
Electrode
Ignitor
Electrode
TO AppLIANCE
pROCEDURE
to the
to the
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cgefp33prcLmfp33nrcLmfp33prc

Table of Contents