Power Policy - Gigabyte H252-3C0 User Manual

Hci server – intel up 2u 4 nodes server with 12 x sata/sas
Table of Contents

Advertisement

5-3-11 Power Policy

Parameter
Power Policy Quick Settings
SpeedStep (Pstates)
Turbo Mode
CPU C6 report
Enhanced Halt State (C1E)
Description
Selects a Power Policy Quick Setting.
Options available: Standard, Best Performance, Energy Efficient, Turbo
Lock. Default setting is Best Performance.
Conventional Intel SpeedStep Technology switches both voltage and
frequency in tandem between high and low levels in response to processor
load.
Options available: Enabled/Disabled. Default setting is Enabled.
When this item is enabled, the processor will automatically ramp up the
clock speed of 1-2 of its processing cores to improve its performance.
When this item is disabled, the processor will not overclock any of its core.
Options available: Enabled/Disabled. Default setting is Enabled.
Allows you to determine whether to let the CPU enter C6 mode in system
halt state. When enabled, the CPU core frequency and voltage will be
reduced during system halt state to decrease power consumption. The C6
state is a more enhanced powersaving state than C1.
Options available: Disabled, Enabled, Auto. Default setting is Disabled.
Core C1E auto promotion control. Takes effect after reboot.
Options available: Enabled/Disabled. Default setting is Disabled.