H263-S62-LAN1 H263-S62-LAW1 Liquid Cooling Solution HPC Server – 4th Gen. Intel Xeon Scalable Server DP 24 x Gen4 NVMe/SATA/SAS HCI & Hybrid/Private Cloud Server Dual 2600W (240V) 80 PLUS Titanium redundant power supply (LAN1) Dual 3000W (240V) 80 PLUS Titanium redundant power supply (LAW1) User Manual Rev.
Page 2
For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller portal: http://reseller.b2b.gigabyte.com For further technical assistance, please contact your GIGABYTE representative or visit https://esupport.gigabyte.com/ to create a new support ticket For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email: server.grp@gigabyte.com...
Page 3
Conventions The following conventions are used in this user's guide: NOTE! Pieces of additional information related to the current topic. CAUTION! Precautionary measures to avoid possible hardware or software problems. WARNING! Alerts to any damage that might result from doing or not doing specific actions.
Page 4
Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
Page 5
Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
Page 6
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that can be gripped with fin-gertips or with a pair of fine needle nosed pliers. If the jumpers do not have such a tab, take care when us- ing needle nosed pliers to remove or install a jumper;...
Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the user manual and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related information without prior notice. Security Server Socket Operating Properties System 2U 4-Node - Rear access Dimension 440 (W) x 87.5 (H) x 840 (D) mm System fan Power Supply 4th Generation Intel®...
Page 12
Storage Per node: 6 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays Total: Socket Security Server Operating Properties 24 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays System fan Power Supply SAS card is required for SAS devices support Supported via add-on SAS Card ...
Page 13
Per Node: Internal I/O 1 x TPM header Per node: Front I/O 1 x Power button with LED Socket Security Server Operating Properties 1 x ID button with LED 1 x Status LED System fan Power Supply ...
Page 14
Security Server Operating Properties System fan Power Supply Power Supply Dual 2600W (240V) 80 PLUS Titanium redundant power supply (LAN1) Available for 2+1 redundant power supply configuration (optional) AC Input: 100-127V~/ 13.8A, 50-60Hz 200-240V~/ 15A, 50-60Hz DC Input: ...
Page 15
System Aspeed® AST2600 management controller Management GIGABYTE Management Console (AMI MegaRAC SP-X) web interface Dashboard Security Server Operating Properties HTML5 KVM Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) System fan Power Supply Sensor Reading History Data ...
System Block Diagram 8-Channel DDR5, 8 x DIMMs 8-Channel DDR5, 8 x DIMMs CPU0 CPU1 Speed up to 4800 MHz Speed up to 4800 MHz 4 x UPI 16 GT/s Gen Intel Xeon Gen Intel Xeon ® ® ® ® Scalable processors Scalable processors (LGA4677 Socket)
Chapter 2 System Appearance Front View NODE1 NODE2 NODE3 NODE4 Decription Front Panel LEDs and buttons NOTE! Drives with green latches support NVMe. • Please Go to Chapter 2-3 Front Panel LED and Buttons for detail description of function LEDs. System Appearance - 17 -...
Rear View PSU2 SLOT3 SLOT2 SLOT1 Decription PCIe Slot ID Button 2 x USB 3.2 Gen1 VGA Port BMC Server Management LAN Port OCP 3.0 Slot (SFF Type) PCIe Slot CMC LAN Port Ring Topology Kit (Option) 2+1 Redundant Power Supply Unit (Option) Coolant Pipe Slot System Appearance - 18 -...
Front Panel LED and Buttons NODE1 NODE3 NODE2 NODE4 No. Name Color Status Description This LED represents the RoT function LED behavior. System Status Please see the following section for detail LED behavior. (Note) Reset Button Press this button to reset the system. Green System is powered on Green...
RoT LEDs NODE3 NODE1 Status LED Status LED ID LED ID LED NODE4 NODE2 Status LED Status LED ID LED ID LED LED on Front panel (Note5) ID LED Status LED EC Firmware (FW) Authentication fail or not exit EC FW is broken or not exit (Note1) Authenticating/Recovering BMC/BIOS Images Authenticating Images...
Page 21
Blinks Blue Blinks Green 2 times per second 2 times per second BMC : AUTH fail after doing recovery (Note3) [ON OFF OFF] [ON OFF OFF] Blinks Blue Blinks Amber 2 times per second 2 times per second BIOS : AUTH fail after doing recovery (Note3) [ON OFF OFF] [ON OFF OFF]...
Rear System LAN LEDs Name Color Status Description Yellow 1Gbps data rate 1GbE Green 100 Mbps data rate Speed LED 10 Mbps data rate Link between system and 1GbE Green network or no access Link/ Blink Data transmission or receiving is occurring Activity LED No data transmission or receiving is occurring System Appearance...
Power Supply Unit LED PSU LED State Description No AC power to all power supplies 1Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updating mode AC cord unplugged or AC power lost; with a second power supply in parallel still with AC input power Amber Power supply critical event causing shut down:...
Hard Disk Drive LEDs HDD Present RAID SKU Rebuilding LED1 Locate HDD Fault Access (No Access) Disk LED Green ON(*1) BLINK (*2) (LED on Back Panel) Amber No RAID configuration Green ON(*1) (via HBA) Removed HDD Slot (LED on Back Panel) Amber Green BLINK (*2)
Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged electrostatic discharge. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
Installing the Hard Disk Drive Read the following guidelines before you begin to install the Hard disk drive: • Take note of the drive tray orientation before sliding it out. • The tray will not fit back into the bay if inserted incorrectly. •...
Removing the Node Read the following guidelines before you begin to replace a node: • To make sure the system operates normally, please power off only the node that will be replaced or reconfigured. Follow these instructions to remove a node: Press the release latch while simultaneously pushing down the tray handle for the node.
Removing Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the system cover: Loosen and remove the six screws securing the back cover. Slide the cover to the rear of the system and remove the cover in the direction of the arrow.
Liquid Cooling Assembly Information The liquid cooling assembly is designed to capture heat from the processors in the node and cool the components. The coolant flow for the assembly is produced by the eight quick disconnects at the rear of the server chassis.
3-4-1 Liquid Cooling Specifications The cold plate assembly in the liquid cooling assembly mounts directly on top of the processors. The retention mechanism for installation on top of the processors is integrated into the cold plate. The liquid coolant contained within the tubes, is a mixture of demineralized water and propylene glycol with the following beneficial features: Anti-Freeze, Anti-Corrosion and Anti Bacterial.
Removing and Installing the Coolant Pipe Module Read the following guidelines before you begin to install the heatsink: • Always turn off the computer and unplug the power cord from the power outlet before installing the heatsink to prevent hardware damage. •...
Installing the CPU and the Coolant Pipe Module Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
Page 34
Loosen the four captive screws securing the carrier assembly to the system. Put the Coolant pipe through the PCIe 1 bracket and put the PCIe bracket and coolant bracket together. Use the retained screw to lock the PCIe 1 bracket. Align the carrier assembly to the CPU socket using the guide pinsand make sure the gold triangle is in the correct orientation.
Installing Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
3-7-2 Installing the Memory Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR4 DIMMs on this motherboard. Follow these instructions to install the Memory: Insert the DIMM memory module vertically into the DIMM slot, and push it down.
Installing the PCI Expansion Card • The PCI riser assembly does not include a riser card or any cabling as standard. To install a PCI card, a riser card must be installed. Follow these instructions to install the PCI Expansion card: Remove the three screw on the riser bracket to the system.
Installing the Mezzanine Card 3-9-1 Installing the OCP 3.0 Mezzanine Card Use of the following type of OCP 3.0 NIC is recommended: • OCP 3.0 SFF with pull tab • OCP 3.0 SFF with ejector latch Follow these instructions to install an OCP 3.0 Mezzanine card: Remove the one screw securing the OCP 3.0 card slot cover.
3-10 Replacing the Fan Assembly • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to replacing a system fan.
3-11 Replacing the Power Supply Follow these instructions to replace the power supply: Pull up the power supply handle and press the retaining clip on the right side of the power supply along the direction of the arrow. At the same time, pull out the power supply by using its handle. Insert the replacement power supply firmly into the chassis.
3-12 Remoing the Power Supply Dummy Cover Follow these instructions to remove the power supply dummy cover: Remove the two screw on the system. Pull up the cover handle, at the same time, pull out the metal cover by using its handle. Insert the replacement power supply firmly into the chassis.
3-13 Cable Routing Motherboard: FP_1 Front IO Board: FP_1 Front Panel LEDs and Buttons Cable Front IO Board: FP_1 System Hardware Installation - 45 -...
Page 46
Sensor Board: LEAK_TOP Leak Sensor Board Cable PCIe Board: CON Sensor Board: LEAK_TOP Leak Sensor Board Cable PCIe Board: CON System Hardware Installation - 46 -...
Page 47
Middle Board: N1_SATA Top Middle Board to HDD Back Plane Board Cable (SATA1) F/ HDD Board: N1 SATA Top Middle Board to HDD Back Plane Middle Board: N3_SATA F/ HDD Board: N3 SATA Board Cable (SATA3) Bottom Middle Board to HDD Back Middle Board: N2_SATA Plane Board Cable (SATA2) F/ HDD Board: N2 SATA...
Page 48
Middle Board: N1_U2_B Top Middle Board to HDD Back Plane Board Cable (NVMe/Node1) F/ HDD Board: N1 U.2 A Top Middle Board to HDD Back Plane Middle Board: N1_U2_A F/ HDD Board: N1 U.2 B Board Cable (NVMe/Node1) Top Middle Board to HDD Back Plane Middle Board: N3_U2_B Board Cable (NVMe/Node3) F/ HDD Board: N3 U.2 A...
Page 49
Middle Board: N2_U2_B Bottom Middle Board to HDD Back Plane Board Cable (NVMe/Node2) F/ HDD Board: N2 U.2 A Bottom Middle Board to HDD Back Middle Board: N1_U2_A F/ HDD Board: N2 U.2 B Plane Board Cable (NVMe/Node2) Bottom Middle Board to HDD Back Middle Board: N4_U2_B Plane Board Cable (NVMe/Node4) F/ HDD Board: N4 U.2 A...
Page 50
Motherboard: SL4_SATA0 On board SATA Cable Motherboard: SL4_SATA1 System Hardware Installation - 50 -...
Page 51
Motherboard: SL4_SATA1 SAS RAID Card Cable RAID Card System Hardware Installation - 51 -...
Page 52
PDB Board: R_MLAN Rera LAN Module Cable LAN Module Board: F_MLAN System Hardware Installation - 52 -...
Jumper Setting Default Enable Clear CMOS 1 2 3 CLR_CMOS CPU0 CPU1 HSMB_SEL BIOS defined SPD_SEL BIOS defined Stop initial power on S3_MASK Normal [Default] when BMC is not ready DP_PLD CPLD debug mode Normal [Default] ME_UPDATE Force ME update Normal [Default] BIOS_PWD Clear supervisor password...
Backplane Board Storage Connector 4-3-1 CBPH7O1 Item Description SlimLine SAS Connector (N1 U.2 A) SlimLine SAS Connector (N1 U.2 B) SlimLine SAS Connector (N2 U.2 A) SlimLine SAS Connector (N2 U.2 B) SlimLine SAS Connector (N3 U.2 A) SlimLine SAS Connector (N3 U.2 B) SlimLine SAS Connector (N4 U.2 A) SlimLine SAS Connector (N4 U.2 B) Proprietary PCIe Slot (x8 slot/ GF_HDD)
Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
Page 57
Main This setup page includes all the items of the standard compatible BIOS. Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
Page 59
Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note1) BMC Firmware Version Displays BMC firmware version information.
Page 60
Parameter Description Memory Frequency Displays the frequency information of the installed memory. System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format. BIOS Setup - 60 -...
Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. BIOS Setup - 61 -...
5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be TPM v1.2 Support available. Options available: Disable, Enable. Default setting is Enable. BIOS Setup - 62 -...
5-2-2 Serial Port Console Redirection Parameter Description Console redirection enables the users to manage the system from a COM1 Console remote location. Redirection (Note) Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items. Please note that this item is configurable when COM1 Console Redirection is set to Enabled.
Page 64
Parameter Description Parity – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
Page 65
Parameter Description Serial Port for Out-of-Band Management / Windows EMS console redirection allows the user to configure Console Redirection Emergency Management Settings to support Out-of-Band Serial Port management. Services (EMS) Console Options available: Enabled, Disabled. Default setting is Disabled. Redirection (Note) Press [Enter] to configure advanced items.
5-2-3 SIO Configuration Description Parameter Displays the AMI SIO driver version information. AMI SIO Driver Version Super IO Chip Logical Device(s) Configuration Press [Enter] to configure advanced items. Use This Device – When set to Enabled allows you to configure the serial port settings. When set to Disabled, displays no configuration for the serial port.
Page 68
Parameter Description PCI Bus Driver Version Displays the PCI Bus Driver version information. SLOT1_OCP3 SLOT2_GZ_2 When enabled, this setting will initialize the device expansion SLOT3_GZ_1 ROM for the related PCIe/OCP slot. GENZ_3_ Options available: Enabled, Disabled. Default setting is Enabled. GENZ_4 I/O ROM (Note1)
5-2-5 USB Configuration Parameter Description USB Configuration USB Devices: Displays the USB devices connected to the system. Enable/Disable the XHCI (USB 3.0) Hand-off support. XHCI Hand-off Options available: Enabled, Disabled. Default setting is Enabled. USB Mass Storage Driver Enable/Disable the USB Mass Storage Driver Support. Support Options available: Enabled, Disabled.
5-2-7 Post Report Configuration Parameter Description Post Report Configuration Error Message Report Enable/Disable the POST Error Message support. Post Error Message Options available: Enabled, Disabled. Default setting is Enabled. Halt On Options available: No Error, All Error. Default setting is No Error. BIOS Setup - 71 -...
5-2-9 Chipset Configuration Parameter Description Defines the power state to resume to after a system shutdown that is due to an interruption in AC power. When set to Last State, the system will return to the active power state prior to shutdown. When set to Restore on AC Power Loss (Note) Power Off, the system remains off after power shutdown.
5-2-10 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
Chipset Menu Chipset Setup menu displays submenu options for configuring the function of Platform Controller Hub(PCH). Select a submenu item, then press <Enter> to access the related submenu screen. BIOS Setup - 75 -...
Description Parameter Processor Configuration Press [Enter] to configure advanced items. CPU Socket 0 Configuration – Core Disable Bitmap(Hex) • Number of Cores to enable. 0 means all cores. FFFFFFF Pre-Socket Configuration means to disable all cores. The maximum value depends on the number of CPUs available.
5-3-2 Common RefCode Configuration Parameter Description Common RefCode Configuration Divide physical NUMA nodes into evenly sized virtual NUMA nodes in ACPI table. This may improve Windows performance on CPUs Virtual Numa with more than 64 logical processors. Options available: Enable, Disable. Default setting is Disable. BIOS Setup - 79 -...
5-3-3 UPI Configuration Description Parameter Press [Enter] to configure advanced items. UPI Status – Press [Enter] to view the Uncore status. Link Frequency Select – Selects the UPI link frequency. – Options available: 12.8GT/s, 14.4GT/s, 16.0GT/s, Auto, Use Per Link Setting.
Page 81
Description Parameter MMIO High Granularity Size – Selects the allocation size used to assign mmioh resources. – Options available: 1G, 4G, 16G, 64G, 256G, 1024G. Default setting is UPI General Configuration 64G. (continued) Clock Modulation Enabled – Options available: Disable, Enable, Auto. Default setting is Auto. BIOS Setup - 81 -...
5-3-4 Memory Configuration Description Parameter Integrated Memory Controller (iMC) When set to Enable, the system enforces Plan Of Record restrictions for DDR frequency programming. Enforce DDR Memory Frequency POR Options available: POR, Disable. Default setting is POR. Configures the maximum memory frequency. If Enforce POR is disabled, user will be able to run at higher frequencies than the Memory Frequency memory support (limited by processor support).
Page 83
Description Parameter Enable/Disable Assert ADR on S5. Assert ADR on S5 Options available: Enabled, Disabled. Default setting is Disabled. Auto is the detected SPD value and use it, otherwise use BIOS Build-in. Get Memory Timing Options available: Auto, BIOS Build-in. Default setting is BIOS Build-in. Press [Enter] to view memory topology with DIMM population Memory Topology information.
Page 84
Description Parameter Leaky bucket time window based interface Hour – Leaky bucket time window based interface hour used for DDR (0-24). – Press the <+> / <-> keys to increase or decrease the desired values. Leaky bucket time window based interface Minute ...
5-3-5 IIO Configuration Description Parameter IIO Configuration Press [Enter] to configure advanced items. ® Intel VT for Directed I/O – Enable/Disable the Intel VT for Directed I/O (VT-d) support function by reporting the I/O device assignment to VMM through DMAR ACPI Tables.
Page 86
Description Parameter Interrupt Remapping – Enable/Disable the interrupt remapping support function. – Options available: Auto, Enable, Disable. Default setting is Auto x2APIC Opt Out – Options available: Enable, Disable. Default setting is Disable. Pre-boot DMA Protection – Options available: Enable, Disable. Default setting is Disable. Press [Enter] to configure advanced items.
5-3-6 Advanced Power Management Configuration Description Parameter Press [Enter] to configure advanced items. SpeedStep (Pstates) – Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor load. – Options available: Enable, Disable. Default setting is Enable. CPU P State Control Turbo Mode ...
Page 88
Description Parameter Press [Enter] to configure advanced items. Enable Monitor MWAIT – Allows Monitor and MWAIT instructions. – Options available: Disable, Enable, Auto. Default setting is Auto. CPU C6 Report CPU C State Control – Enable/Disable CPU C6(ACPI C3) report to OS. –...
5-3-7 PCH Configuration Description Parameter PCH-IO Configuration Press [Enter] to configure advanced items. SATA Configuration – Enable/Disable SATA controller. – Options available: Enabled, Disabled. Default setting is Enabled. SATA Mode Selection – Configures on chip SATA type. – AHCI Mode: When set to AHCI, the SATA controller enables its AHCI functionality.
Page 90
Description Parameter Port 0/1/2/3/4/5/6/7 – Enable/Disable Port 0/1/2/3/4/5/6/7 device. – Options available: Enabled, Disabled. Default setting is Enabled. Hot Plug (for Port 0/1/2/3/4/5/6/7) SATA And RST – Enable/Disable HDD Hot-Plug function. Configuration/ – Options available: Enabled, Disabled. Default setting is Enabled. SATA Controller And RST Spin Up Device (for Port 0/1/2/3/4/5/6/7) Configuration (continued)
5-3-9 Server ME Configuration Parameter Description General ME Configuration Oper. Firmware Version Displays the operational firmware version. ME Firmware Status #1/#2 Displays ME Firmware status information. Current State Displays ME Firmware current status information. Error Code Displays ME Firmware status error code. Recovery Cause Displays ME Firmware recovery cause.
5-3-11 Power Policy Description Parameter Selects a Power Policy Quick Setting. Options available: Standard, Best Performance, Energy Efficient. Default Power Policy Quick Settings setting is Standard. Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor SpeedStep (Pstates) load.
Page 96
Description Parameter Enables Logical processor (Software Method to Enable/Disable Logical Processor threads). Enable LP [Global] Options available: ALL LPs, Single LP. Default setting is ALL LPs. Options available: Enable, Disable. Default setting is Enable. Hardware Prefetcher Options available: Enable, Disable. Default setting is Enable. Adjacent Cache Prefetch Options available: Enable, Disable.
Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Options available: Enabled, Disabled. Default setting is Enabled. FRB-2 Timer Configures the FRB2 Timer timeout. The value is between 1 to 30 minutes. (Note1) timeout Default setting is 6 minutes. Configures the FRB2 Timer policy.
Page 98
Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC VLAN Press [Enter] to configure advanced items. Configuration BMC network Press [Enter] to configure advanced items. Configuration IPv6 BMC Network Press [Enter] to configure advanced items.
5-4-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Enabled, Disabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Options available: No, Erase SEL Yes, On next reset,...
5-4-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 100 -...
5-4-3 BMC VLAN Configuration Description Parameter BMC VLAN Configuration Select to configure BMC VLAN ID. The valid range is from 0 to 4094. When BMC VLAN ID set to 0, BMC VLAN ID will be disabled. Select to configure BMC VLAN Priority. The valid range is from 0 to 7. BMC VLAN Priority When BMC VLAN ID is set to 0, BMC VLAN Priority will not be selected.
5-4-5 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
5-5-1 Secure Boot The Secure Boot submenu is applicable when your device is installed the Windows 8 (or above) operating ® system. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function. Secure Boot Options available: Enabled, Disabled.
Page 106
Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
Page 107
Parameter Description Authorized TimeStamps (DBT) – Displays the current status of the Authorized TimeStamps Database. – Press [Enter] to configure a new DBT or load additional DBT from storage devices. Key Management – Options available: Update, Append. (continued) OsRecovery Signatures ...
Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
Page 109
Parameter Description FIXED BOOT ORDER Priorities Press [Enter] to configure the boot order priority. By default, the server searches for boot devices in the following sequence: Hard drive. Boot Option #1 / #2 / #3 / #4 / #5 CD-COM/DVD drive. USB device.
Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save and Exit Options available: Yes, No.
Page 111
Parameter Description Loads the default settings for all BIOS setup parameters. Setup Defaults are quite demanding in terms of resources consumption. If you are using low-speed memory chips or other kinds of low-performance components Restore Defaults and you choose to load these settings, the system might not function properly.
BIOS Recovery The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: 1.
BIOS POST Beep code (AMI standard) 5-9-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...