SunSpec Register Blocks (cont.)
R/W NV Format Units
• • 40125
R
NV
ULong
• • 40126
• • 40127
R
NV
ULong
• • 40128
• • 40129
R
NV
ULong
• • 40130
• • 40131
R
NV
ULong
• • 40132
• • 40133
R
NV
ULong
• • 40134
• • 40135
R
NV
ULong
• • 40136
• • 40137
R
NV
ULong
• • 40138
• • 40139
R
NV
ULong
• • 40140
• • 40141
R
NV
UInt
• • 40142
R
NV
ULong
• • 40143
• • 40144
R
NV
ULong
• • 40145
• • 40146
R
NV
ULong
• • 40147
• • 40148
R
NV
ULong
• • 40149
• • 40150
R
NV
ULong
• • 40151
• • 40152
R
NV
ULong
• • 40153
• • 40154
R
NV
ULong
• • 40155
• • 40156
R
NV
ULong
• • 40157
• • 40158
R
NV
ULong
• • 40159
• • 40160
R
NV
ULong
• • 40161
• • 40162
R
NV
ULong
• • 40163
• • 40164
R
NV
ULong
• • 40165
• • 40166
R
NV
ULong
• • 40167
ZL0122-0D
Page 32 of 34
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Aerospond, Veris, and the Veris 'V' logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
Scale
Range
Apparent Energy
VA-
M_Energy_VA_SF
0x0 to 0xFFFFFFFF M_Exported_VA
hours
VA-
M_Energy_VA_SF
0x0 to 0xFFFFFFFF M_Exported_VA_A Phase A Exported Apparent Energy
hours
VA-
M_Energy_VA_SF
0x0 to 0xFFFFFFFF M_Exported_VA_B Phase B Exported Apparent Energy
hours
VA-
M_Energy_VA_SF
0x0 to 0xFFFFFFFF M_Exported_VA_C Phase C Exported Apparent Energy
hours
VA-
M_Energy_VA_SF
0x0 to 0xFFFFFFFF M_Imported_VA
hours
VA-
M_Energy_VA_SF
0x0 to 0xFFFFFFFF M_Imported_VA_A Phase A Imported Apparent Energy
hours
VA-
M_Energy_VA_SF
0x0 to 0xFFFFFFFF M_Imported_VA_B Phase B Imported Apparent Energy
hours
VA-
M_Energy_VA_SF
0x0 to 0xFFFFFFFF M_Imported_VA_C Phase C Imported Apparent Energy
hours
SF
1
Reactive Energy
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF M_Import_VARh_Q1 Quadrant 1: Total Imported Reactive Energy
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF M_Import_VARh_Q2 Quadrant 2: Total Imported Reactive Energy
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF M_Export_VARh_Q3 Quadrant 3: Total Exported Reactive Energy
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF
hours
VAR-
M_Energy_VAR_SF
0x0 to 0xFFFFFFFF M_Export_VARh_Q4 Quadrant 4: Total Exported Reactive Energy
hours
©2018 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
Other companies' trademarks are hereby acknowledged to belong to their respective owners.
SunSpec Name
Total Exported Apparent Energy
Total Imported Apparent Energy
M_Energy_VA_SF
Real Energy Scale Factor
M_Import_VARh_
Phase A - Quadrant 1: Total Imported Reactive Energy
Q1A
M_Import_VARh_
Phase B - Quadrant 1: Total Imported Reactive Energy
Q1B
M_Import_VARh_
Phase C - Quadrant 1: Total Imported Reactive Energy
Q1C
M_Import_VARh_
Phase A - Quadrant 2: Total Imported Reactive Energy
Q2A
M_Import_VARh_
Phase B - Quadrant 2: Total Imported Reactive Energy
Q2B
M_Import_VARh_
Phase C - Quadrant 2: Total Imported Reactive Energy
Q2C
M_Export_VARh_
Phase A - Quadrant 3: Total Exported Reactive Energy
Q3A
M_Export_VARh_
Phase B - Quadrant 3: Total Exported Reactive Energy
Q3B
M_Export_VARh_
Phase C - Quadrant 3: Total Exported Reactive Energy
Q3C
TM
Description
0818