Kitchen unit with door
A
60 mm
B

Technical information

Hob dimensions
Width
Depth
Bypass diameters
BURNER
Rapid
Auxiliary
Other technical data
TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
www.zanussi.com
30 mm
min 20 mm
(max 150 mm)
42
28
Gas original:
Gas replacement:
230 V ~ 50 Hz
II2H3+
G 1/2"
3
A) Removable panel
B) Space for connections
Kitchen unit with oven
The electrical connection of the hob and the
oven must be installed separately for safety
reasons and to let easy remove oven from the
unit.
290 mm
510 mm
Ø BYPASS 1/100 mm
G20 (2H) 20 mbar = 4,0 kW
G30 (3+) 28-30 mbar = 276 g/h
G31 (3+) 37 mbar = 271 g/h