Seal using silicone rub-
ber around the circle
Twist
EN
Start Point (Long
Set Point (Short
Indicator)
Indicator)
Camera Removal for Maintenance
In order to perform maintenance or change hardware setting, remove lower dome cover
first and unlock the camera assembly by turning in the direction indicated by the arrows
in the figure below to remove the PTZ camera.
Unlock
Lock
Remove bubble
Torx screw (M4)
9