If you connect a gateway lock to the system, you must enable this feature, set "Unlock time " and by lock
type "Unlock signal type" (normally open or normally closed).
33. Type of outgoing button
Set the target of the outbound button control on the door or gateway, depending on the actual
installation. Press the exit button to open the door/gate lock.
34. Status assigned from the washing machine
Related information about the device will not be displayed until it is connected from the device to the
system.
35. Status of the elevator controller
You can enable/disable the elevator control function.
Note: This feature only works if an elevator control module is installed on the system.
36. Setting the security parameters of the input unit
(depending on the type).
37. Tamper
(protective contact when the cover is opened illegally) after activation of this function
a security contact will be activated in the input station, tamper and if someone tampers with the entrance
station an alarm will be triggered. The room number must also be set to receive the tamper alarm.

38. Check the condition of the door

If this function is enabled the system checks the door status after the longest opening time door. Set
"Magnetic Contact Type" according to door lock type (normally open or normally closed). Set "Longest
opening time". Once the door is open the entrance station will check their status for the longest opening
time set. If the door is not closed after the longest opening time set, a beep will sound from the entrance
station.
39. Adjust the volume of the bell speaker.
You can adjust the volume from 10% to 100% as needed.
40. Adjust the angle of view
You can set the angle of view for the entry station. Press the menu to set the angle of view from the entry
station. Touch the location on the screen where it wants to get closer.
Press the tracking icon
to exit. Finally, tap the return icon in the upper-left corner of the screen and
press the confirm settings icon to save the settings. When it rings from the entrance station, the set image
appears.
41. Set a password to configure a door lock
The password can be up to 8 digits, the first digit must not be 0.

42. Setup mode

It is turned on by default. If enabled, you can set "Room Address" and "Floor" for monitors on the network.
If it is turned off at all entry stations network, you will not be able to change the address of any monitor. If
you don't want users to accidentally change the address of your monitors, turn off this feature on all input