Important Notes For Component Replacement; Maintenance; Condenser - Hoshizaki BB59 Service Manual

R290 back bar equipment
Table of Contents

Advertisement

10) If necessary, add any remaining charge to the system through the low-side.
NOTICE! To prevent compressor damage, use a throttling valve or
liquid dispensing device to add the remaining liquid charge through
the low-side access valve with the appliance running.
11) Close gauge manifold valves and disconnect the hoses.
12) Cap the access valve to prevent a possible leak
B. Important Notes for Component Replacement
• When replacing a component listed below, see the notes to help ensure proper
operation.
Components
Compressor
Install a new start relay, start capacitor, and compressor protector
(compressor protector is integrated with the start relay).
Compressor,
WARNING! To reduce the risk of electric shock, be sure to
Evaporator
reconnect the component's ground wire.
Fan Motor,

Condenser

Fan Motor
Controller
Be sure all the wiring lines are attached at the correct position on
terminals, wait 3-min. to see if the compressors turn on.
V. Maintenance
• Move the power switch to the "OFF" position and unplug the appliance before
performing maintenance to prevent electric shock or injury by moving parts. To
reduce the risk of electric shock, do not touch the power switch or plug with damp
hands.
• Before performing maintenance, move all beverages into another clean refrigerator.
WARNING
Notes
WARNING
26

Advertisement

Table of Contents
loading

Table of Contents