NO
Vali
Name
Def.
A B C
.
d
Basic Set
2
0xFF
All
Level
5
Operation
(*)
Mode
0
All
0
0
0
0
0
0
Description
Setting the BASIC command value to
turn on the light. The 0xFF(-1) means
turn on the light. For dimmer
equipment 1 to 100 means the light
strength.
0 means turn off the light.
Caution: The value is unsigned byte,
the range is from 0x00 ~ 0xFF.
Operation mode. Using bit to control.
Caution: The value is unsigned byte,
the range is from 0x00 ~ 0xFF.
Bit0: Reserve.
Bit1: 1 means test mode,
0 means normal mode.
Notice:
This bit only effect by the DIP Switch
setting to "customer mode", otherwise
it decides by DIP Switch setting to
Test or Normal Mode.
Bit2: Disable the door/window
function. (1:Disable, 0:Enable)
Bit3: Setting the temperature scale.
0: Fahrenheit , 1: Celsius
Bit4: Disable the illumination report
after event triggered. (1:Disable,
0:Enable)
Bit5: Disable the temperature report
after event triggered. (1:Disable,
0:Enable)
NO
Vali
Name
Def.
.
d
0
0
4
All
0
0
7
Customer
(*)
Function
0
0
0
0
Auto
Report
0 ~
10
12
Battery
127
Time
11
12
Auto Report
0 ~
6
Description
A B C
Bit6: Reserve.
Disable the back key release
Bit7:
into test mode. (1:Disable,
0:Enable)
Customer function switch, using bit
control.
Caution: The value is unsigned byte,
the range is from 0x00 ~ 0xFF.
Bit0: Reserve.
Bit3: Disable send out BASIC OFF
after door closed. (1:Disable,
0:Enable)
Bit4: Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.
Bit5: Disable Multi CC in auto report.
(1:Disable, 0:Enable)
Bit6: Disable to report battery state
when the device triggered. (1:Disable,
0:Enable)
Bit7: Reserve.
The interval time for auto report the
battery level.
0 means turn off auto report battery.
The default value is 12. The tick time
can setting by the configuration No.20.
The interval time for auto report the