7.2 Switching off the appliance
Switch the appliance off when you are not using it.
Press
to switch the appliance off.
a The appliance switches off. Any functions currently
in progress are cancelled.
7.3 Selecting a fan setting
Press
 or
⁠ .
a The LED for the set fan setting lights up in the LED
display.
7.4 Switching on intensive mode
If particularly strong odours or vapours develop, you
can use intensive mode.
 so oft drücken, bis in der LED-Anzeige die LED 4
1.
für die Intensivstufe 1 leuchtet.
 so oft drücken, bis in der LED-Anzeige die LED 5
2.
für die Intensivstufe 2 leuchtet.
a After approx. 6 minutes, the appliance automatically
switches to fan setting 3.
7.5 Switching off intensive mode
To select a fan setting of your choice, press
7.6 Switching on the fan run-on
Press
⁠ .
a LED 1 for the fan setting lights up in the LED dis-
play. LED 6 flashes for the fan run-on.
a The appliance switches off automatically after ap-
prox. 10 minutes.
7.7 Switching off the fan run-on
Press
⁠ .
a This immediately stops the fan run-on.
a The appliance switches to the fan setting that was
previously selected.
7.8 Switch on automatic mode
The optimum fan setting is set automatically using a
sensor.
Press
⁠ .
a In the LED display, LED 6 lights up for automatic
mode.
7.9 Switch off automatic mode
Press
⁠ .
a The appliance switches to the fan setting that was
previously set.
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
1
Depending on the appliance specifications
⁠ .
1
1
7.10 Intermittent ventilation
With interval ventilation, the ventilation system switches
on and off in the selected setting for the selected time.
Note: This function is only available via a mobile device
with the Home Connect app.
If the interval ventilation is switched on, LED 6 continu-
ously flashes in the LED display for the interval ventila-
tion and the LED for the selected fan setting lights up.
As soon as the ventilation time ends, the LED for the
fan setting you have selected goes out. LED 6 contin-
ues to flash.
7.11 Sensor control
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting is automatically switched on.
If the sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Default setting: Fan setting 3
¡ Lowest setting: Fan setting 1
¡ Highest setting: Fan setting 5
7.12 Setting the sensor control
Requirement: The appliance is switched off.
Press and hold
 and
1.
2.
Press
 or 
to change the setting.
To cancel the setting, press  ⁠ .
To save the setting, press and hold
3.
prox. 3 seconds.
Or wait approx. 10 seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
7.13 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement: The appliance is switched off.
Press and hold
 and
1.
To set circulating-air mode (non-regenerable fil-
ter), press
⁠ /
until LED 2 lights up in the LED
display.
To set circulating-air mode (non-regenerable fil-
ter), press
⁠ /
until LED 3 lights up in the LED
display.
To convert the electronic control back to opera-
tion without the air recirculation filter, press
until LED 1 lights up on the LED display.
To save the setting, press and hold   and   for ap-
2.
prox. three seconds.
Or wait approx. 10 seconds until the setting is
saved automatically.
To cancel the setting, press  ⁠ .
a A signal tone sounds as soon as the selected set-
ting is saved.
Basic operation en
1
1
 for approx. 3 seconds.
 and 
 for approx. three seconds.
for ap-
⁠ /
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

I95caq6.0I95caq6.0b

Table of Contents