CUT-OUT DIMENSIONS FOR BUILT-IN GRILLS
Note: Side burners may be rotated 90 degrees.
Note: For Natural Gas grills, the manufacturer
recommends using 3/4" gas supply lines.
Locate a 110 V 15Amp
GFI outlet for rotisserie
models.
12.00"
A
Single &
Double Side
Burner (LSB)
Double
Drawers
(LUD)
BUILT-IN GRILL
Model
A
L500
29.00
L600
35.00
L700
41.00
BUILT-IN GRILL W/ INSULATING JACKET
Model
A
LIJ500
36.00
LIJ600
42.00
LIJ700
48.00
COMPLEMENTARY PRODUCTS
Model
A
LSB501
11.00
LSB502
21.00
LDR424
22.00
LDR530
28.25
LDR636
33.75
LSA530
28.25
LSA636
33.75
LUD517
17.25
L500REF
21.50
CUTOUT NOT
REQUIRED
WITH LIJs
A
C
2.25"
2.00"
3.50"
B
3.50"
B
Door & Drawer Options
(LDR, LSA or LTA)
A
A
B
C
10.00
21.25
10.00
21.25
10.00
21.25
B
C
11.62
23.25
11.62
23.25
11.62
23.25
B
C
4.00
16.00
4.00
16.00
19.00
19.00
19.00
19.00
20.00
19.00
20.00
12.75
20.00
34.00
24.50
0.56"
34.00"
Outdoor
Refrigerator
(L500REF)
21.50"
*
When installing the LSB side burners
over the refrigerator, the counter top
must be at least 37-1/2" above the floor.
An enclosure for an LP-gas cylinder shall be ventilated by openings at
both the upper and lower levels of the enclosure. The effectiveness of the
opening(s) for purposes of ventilation shall be determined with the LP-gas
supply cylinder in place. This shall be accompanied by one of the following:
a) One side of the enclosure shall be completely open; or
b) For an enclosure having four sides, a top and a bottom:
1. At least two ventilation openings shall be provided in the side walls of the
enclosure, located within 5 in (217 mm) of the top of the enclosure, equally
sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. The
opening(s) shall have a total free area of not less than 1 in 2/ lb (14.2 cm2/kg) of
stored fuel capacity.
2. Ventilation opening(s) shall be provided at floor level of the enclosure and shall
have a total free area of not less than 1/2 in 2/lb (7.1 cm2/kg) of stored fuel
capacity. If ventilation openings at floor level are in a side wall, there shall be
at least two openings. The bottom of the openings shall be 1 in (25.4 mm) or
less from the floor level and the upper edge no more than 5 in (127 mm) above
the floor level. The openings shall be equally sized, spaced at a minimum of 90
degrees (1.57 rad) and unobstructed.
3. Every opening shall have minimum dimensions so as to permit the entrance of
a 1/8 in (3.2 mm) diameter rod.
4. Ventilation openings in side walls shall not communicate directly with other
enclosures of the outdoor cooking gas appliance.
Keep the ventilation openings of the cylinder enclosure free and clear from
debris.
UNCONVENTIONAL ISLAND INSTALLS
If building an island that does not conform to the standard
properties listed in the following pages, please contact Lynx
Grills at 888-259-5969 to verify all safety requirements
regarding installation have been met.
COUNTERTOP
NOTCH DETAIL
Only required if island
countertop overhangs
the face of the island
Depth equals
countertop
overhang
9/16" for Grills
1/2" for Complementary Products
C
A
5"
4.5"
3"
B
INSULATING JACKET
NOTE: Insulating jacket
required for all grills
installed into a combustible
enclosure.