GAS CONNECTIONS... continued
Ensure that the gas supplied meets with the minimum
pressure requirements. Do not operate the grill on any gas
other than that for which the grill has been set.
Fuel
WC Max Inlet
Nat Gas
10 in
LP
14 in
Water Column Requirements
Both the regulator and the manifold orifices have been
tuned for the type of gas specified on the rating plate.
All installation and all installation parts must conform
to local codes with the National Electrical Code, ANSI
Z223.1/NFPA 70 latest edition and the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 in the U.S and
CGA-B149.1/.2 in Canada.
Canadian installations must conform to CGA-B149.1/.2
natural gas/propane installation code. (Canada)

NATURAL GAS

It is recommended that only qualified professionals
perform the required plumbing on this product.
To ensure satisfactory performance, the gas supply line
must be sized to accommodate the total BTU requirements of
Built in
all the gas-fired equipment that will be connected to that line.
In no case should pipe less than ¾" inside diameter or 1"
outside diameter ever be used to connect this product.
• Calculate the total BTU output of all equipment and
WC Min Under Full
Load
4 in
11 in
• Always keep supply line runs as short as possible. (See
• A gas shut-off valve must be installed in an easily
• Keep threading compound off of the first two pipe
For built-in installations, it is recommended that any flexible
pipe used be kept as short as possible. (See INDEX: "Gas
Connections" for typical permanent hook up.)
*
Freestanding
*also for bulk
propane
refer to "INDEX: Gas Supply Line Runs" for allowable run
distances for ¾ inch pipe. Failure to meet these minimum
requirements may reduce performance of the grill and
any other appliances running on that supply line.
INDEX: "BTU Output" for specific model outputs)
accessible location by a qualified plumber.
threads to avoid having any small pieces of compound
break loose and clog a burner valve or orifice. Do not use
threading compound on any flare fittings.
Keep last two
threads clean
SEDONA CARE & USE/INSTALLATION
|