1-6. RS-485 connection
① This device has 1 data port (RS-485).
② Use this port to connect the PTZ camera.
③ PTZ camera
i.
Connect the PTZ serial communication cable to the RS-485 port.
ii.
When connecting the cable, make sure that the TX- of the device is connected to the
RX- (TX-) of the camera(keyboard), and TX+ of the device is connected to the
RX+(TX+) of the PTZ camera(keyboard).
iii. Recommended initial data setting is 9600 baud rate, 8 data bits, 1 stop bit and no
parity.
iv. When connecting the PTZ camera or keyboard, always change the setting of the DVR
setting menu according the RS-485 setting of the camera, keyboard and this device.
1-7. Control port (output) connection
① For interface and auto control with the external sensor, the interfacing control output port
(Set value from "Setup Event Sensor/Motion/Video loss" menu) and the "RELAY" port
are connected.
② If the control device (Alarm light, amplified siren, external relay etc.) is "NC (Normal
Close)" type, connect to the control output NC (Normal Close) port.
③ If the control device (Alarm light, amplified siren, external relay etc.) is "NO (Normal
Open)" type, connect to the control output NO (Normal Open) port.
11
U
'
M
SER
S
ANUAL
H.264 R
T
DVR
EAL
IME