Yamaha Clavinova CLP-120 Owner's Manual page 46

Yamaha clavinova owner;s manual clp-130, clp-120
Hide thumbs Also See for Clavinova CLP-120:
Table of Contents

Advertisement

F8.2:
/F7.2:
(CLP-130)
MIDI Receive Channel Selection
In any MIDI control setup, the MIDI channels of the
transmitting and receiving equipment must be matched
for proper data transfer. This parameter enables you to
specify the channel on which the Clavinova receives
MIDI data.
Setting range:
Normal setting: ALL
ALL:
A "Multi-timbre" Receive mode is available. It allows simulta-
neous reception of different parts on all 16 MIDI channels,
enabling the Clavinova to play multi-channel song data
received from a music computer or sequencer.
1&2:
A "1&2" Receive mode is available. It allows simultaneous
reception on channels 1 and 2 only, enabling the Clavinova to
play 1 and 2 channel song data received from a music com-
puter or sequencer.
Program change and other like channel messages received
will not affect the CLP-130/120's panel settings or the notes
you play on the keyboard.
No MIDI reception occurs when Demo/Preset Song mode is
engaged.
F8.3:
/F7.3:
(CLP-130)
Local Control ON/OFF
"Local Control" refers to the fact that, normally, the
CLP-130/120 keyboard controls its internal tone genera-
tor, allowing the internal voices to be played directly
from the keyboard. This situation is "Local Control On,"
since the internal tone generator is controlled locally by
its own keyboard.
Local control can be turned OFF, however, so that the
CLP-130/120 keyboard does not play the internal voices,
but the appropriate MIDI information is still transmitted
via the MIDI OUT connector when notes are played on
the keyboard. At the same time, the internal tone genera-
tor responds to MIDI information received via the MIDI
IN connector.
Setting range:
Normal setting: ON
46
Detailed Settings – [FUNCTION]
CLP-130/120
(CLP-120)
ALL, 1&2, 1 – 16
TIP
TIP
NOTE
(CLP-120)
ON/OFF
F8.4:
/F7.4:
(CLP-130)
(CLP-120)
Program Change ON/OFF
Normally the CLP-130/120 will respond to MIDI pro-
gram change numbers received from an external key-
board or other MIDI device, causing the
correspondingly-numbered voice to be selected on the
corresponding channel (the keyboard voice does not
change). The CLP-130/120 will normally also send a
MIDI program change number whenever one of its
voices is selected, causing the correspondingly-num-
bered voice or program to be selected on the external
MIDI device if the device is set up to receive and respond
to MIDI program change numbers.
This function makes it possible to cancel program
change number reception and transmission so that
voices can be selected on the CLP-130/120 without
affecting the external MIDI device.
For information on program change numbers for each of the
CLP-130/120's voices, refer to page 71 in the MIDI Data For-
mat section.
Setting range:
ON/OFF
Normal setting: ON
F8.5:
/F7.5:
(CLP-130)
(CLP-120)
Control Change ON/OFF
Normally the CLP-130/120 will respond to MIDI control
change data received from an external MIDI device or
keyboard, causing the voice on the corresponding chan-
nel to be affected by pedal and other "control" settings
received from the controlling device (the keyboard voice
is not affected).
The CLP-130/120 also transmits MIDI control change
information when the pedal or other appropriate con-
trols are operated.
This function makes it possible to cancel control change
data reception and transmission so that, for example, the
CLP-130/120's pedal and other controls can be operated
without affecting an external MIDI device.
For information on control changes that can be used with the
CLP-130/120, refer to the MIDI Data Format on page 71.
Setting range:
ON/OFF
Normal setting: ON
TIP
TIP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clavinova clp-130

Table of Contents