Bradley S19-320B Installation Manual

Bradley S19-320B Installation Manual

Flow switch alarm system with 120/24vac transformer

Advertisement

215-693B Rev. F; ECN 07-512A
© 2008 Bradley Corporation
Page 1 of 6
11/17/08
S19-320B (6' cable)
S19-320E (12' cable)
Flow Switch Alarm System with
120/24VAC Transformer
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . . . . . .2
Assembly Of Components . . . . . . . . . . . . . . . . . . . . .3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Testing The Alarm System . . . . . . . . . . . . . . . . . . . . .5
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Strobe Flashtube Replacement. . . . . . . . . . . . . . . . . .5
Alarm System Maintenance. . . . . . . . . . . . . . . . . . . .6
Remote Sensing Option. . . . . . . . . . . . . . . . . . . . . . .6
P.O. Box 309, Menomonee Falls, WI USA 53052-0309
PHONE 800.BRADLEY (800.272.3539) FAX 262.251.5817
bradleycorp.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S19-320B and is the answer not in the manual?

Questions and answers

Summary of Contents for Bradley S19-320B

  • Page 1 Remote Sensing Option..... . .6 215-693B Rev. F; ECN 07-512A P.O. Box 309, Menomonee Falls, WI USA 53052-0309 © 2008 Bradley Corporation PHONE 800.BRADLEY (800.272.3539) FAX 262.251.5817 bradleycorp.com Page 1 of 6 11/17/08...
  • Page 2 15 amp branch circuit with a dedicated circuit breaker or fuse and should not supply power to any other device. Compliance and conformity to local codes and ordinances is the responsibility of the installer. 11/17/08 Bradley Corporation • 215-693B Rev. F; ECN 07-512A...
  • Page 3 Body Blue Green Brass Black Adapter and Tee 3.6" (91mm) 1-1/4" NPT Electrical Inlet and Connections Outlet IMPORTANT! Power Supply System is prewired. Installer connects ONLY ground black and white wires! Bradley Corporation • 215-693B Rev. F; ECN 07-512A 11/17/08...
  • Page 4 1. Connect the 24 volt AC power to the Alarm System (using the red and black wires only) in the 6- or 12-foot power cable provided. Test the alarm system. 11/17/08 Bradley Corporation • 215-693B Rev. F; ECN 07-512A...
  • Page 5 S19-120ABF S19-120SS E19-120SS S19-120SSBF S19-120T S19-120HFP Flow Switch optional location (recommended location for brass fl ow switch is inside of wall) To 1-1/4" Water Supply Piping supplied by installer Application S19-310PVC Bradley Corporation • 215-693B Rev. F; ECN 07-512A 11/17/08...
  • Page 6 7. Test the alarm as described in “Test the Alarm System.” Alarm system maintenance The Bradley Alarm System is designed to be virtually maintenance free. An occasional damp cloth wiping of the clear dust cover is all that is needed to ensure maximum visual attention-getting ability.