C
HANGES IN MANUAL FOR THE WORK AND THE SOFTWARE OF THE CONTROLLER
User
Manual
version
3.2
Software version amended to 27/14.
•
New way of dismissing the alarms for registered problems. Most of them
•
are automatically dismissed as soon as the reason for them is no longer
present. Alarms caused by more serious events require manual dismissal by
pressing the left navigation button "◄" for more than 2 seconds.
New appearance of the "Information" screen and the "Equipment" menu
•
3.3
Software version amended to 28/14.
•
Alphabetical order of the languages: Bulgarian, English, Latvian, Portugal
•
and Spanish.
Added option to work with additional "Control module" with room
•
thermostat functions NRC-6 SV
3.4
Software version amended to 31/15.
•
In case the burner is currently off (due to reached set temperature, for
•
instance), but it is about to turn on and if there is a timer scheduled to turn it
off in 10 minutes or less, the burner will remain off, because otherwise the
extinguishing procedure may begin before the fire is stabilized.
If OD input activates during Ignition or Unfolding procedures, the
•
extinguishing procedure begins only after switching to any of the power
levels.
3.5
Software version amended to 32/16.
•
If the burner is on and timers are active, holding the On/Off button for more
•
than 2 seconds deactivates the timers.
Loading first dose time increased to 240 seconds
•
Version screen displays software and hardware version of the controller, as
•
well as WiFi modem's software version if it is 24
3.6
Software version amended to 34/16.
•
Main auger's capacity increased to 350 kg/h.
•
Consumed pellets graphic's scales increased to 5, 10, 20, 40, 80 and 160
•
kg / h
Minimum value for ignition/extinction level of illumination set to 1
•
Ignition's level of illumination value must be higher than extinction's.
•
Added Russian language.
•
3.7
Software version amended to 40/18
•
Switch mode choice between Standby, On and Timers
•
New menu in User settings for fuel selection
•
User Manual / ver 3.7
Controller for pellet oven – NPBC-V3C-B
Changes
http://www.naturela-bg.com/en/
or higher
page 2 of 30
Page
1
11
16
17
17
15