Section 7
Host Communications Specifications

GET MULTI-READER/WRITER STATUS

This command reads the Master Reader/Writer and Slave Reader/Writer status when multi-Reader/
Writer operation is being used.
 Command Area
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
 Response Area
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespData/Response Data
Master Status
Slave No. 1 Status
:
Slave No. 7 Status
 Execution Example
Reading the Multi-Reader/Writer Status When the Reader/Writer Is in Field Extension Mode, the
Group Is Being Detected, Connection of Slave Reader/Writer No. 2 Failed, and Slave Reader/Writers
No. 3 to 7 Are Not Connected
Command Area
Memory offset
+1
+2
+3
Response Area
Memory offset
+1
+2
+3
+4
+5
+6
+7
+8
+9
+10
+11
RFID System
180
User's Manual
(EtherNet/IP
TM
)
Signal/data
Data type
WORD
WORD
WORD
Signal/data
Data type
WORD
WORD
WORD
WORD
WORD
WORD
Data name
bit15-12 bit11-8
CmdCode
2
0
CmdParam1
0
0
CmdParam2
0
0
Data name
bit15-12 bit11-8
ErrCode
0
0
RespInfo1
0
0
RespInfo2
0
0
RespData[0-1]
1
0
RespData[2-3]
0
0
RespData[4-5]
0
0
RespData[6-7]
0
0
RespData[8-9]
0
0
RespData[10-11]
0
0
RespData[12-13]
0
0
RespData[14-15]
0
0
Size
2 bytes
2006 hex
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
Size
2 bytes
Error code
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
Multi-Reader/Writer status of Master Reader/Writer
0000 hex: Disable
1000 hex: Preparing for Field Extension Mode
(Detecting Groups)
1001 hex: Ready for Field Extension Mode (Group
2 bytes
Detection Completed)
2000 hex: Preparing for High-speed Traveling Mode
(Detecting Groups)
2001 hex: Ready for High-speed Traveling Mode
(Group Detection Completed)
Connection status of Slave Reader/Writers No. 1 to 7
2 bytes
0000 hex: Not connected.
:
:
0001 hex: Connection successful
0002 hex: Connection failed
2 bytes
bit7-4
bit3-0
0
6
0
0
0
0
bit7-4
bit3-0
0
0
0
0
0
0
Master Reader/Writer
0
0
Slave Reader/Writer No. 1
0
1
Slave Reader/Writer No. 2
0
2
0
0
Slave Reader/Writer No. 3
Slave Reader/Writer No. 4
0
0
Slave Reader/Writer No. 5
0
0
0
0
Slave Reader/Writer No. 6
0
0
Slave Reader/Writer No. 7
Description
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680s seriesV680s-hmd63-eipV680 seriesV680s-hmd66-eip

Table of Contents