Gree GIM09AE Owner's Manual

Gree GIM09AE Owner's Manual

Split air conditioner

Advertisement

Quick Links

Split Air Conditioner
GIM09AE/GIM09AC
GIM12AE/GIM12AC
GIM18AE/GIM18AC
Thank you for choosing our product.
For proper operation, please read and keep this manual carefully.
If you have lost the Owner's Manual, please contact the local agent.

Advertisement

Table of Contents
loading

Summary of Contents for Gree GIM09AE

  • Page 1 Split Air Conditioner GIM09AE/GIM09AC GIM12AE/GIM12AC GIM18AE/GIM18AC Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner’s Manual, please contact the local agent.
  • Page 3: Table Of Contents

    Content Operation Notices Precautions......................1 Parts name ......................6 Screen Operation Guide Buttons on remote controller .................8 Introduction for buttons on remote controller ............9 Function introduction for combination buttons .............15 Operation guide ....................18 Replacement of batteries in remote controller .............18 Emergency operation ..................19 Maintenance Clean and maintenance..................19 Malfunction...
  • Page 4 Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 5: Precautions

    Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 7 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 8 Precautions WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 9 Precautions WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 10: Parts Name

    Parts Name Indoor Unit air inlet panel aux.button horizontal louver air outlet (Display content or position may be different from above graphics, please refer to actual products) remote control Outdoor Unit air inlet air outlet NOTICE: Actual product may be different from above graphics, please refer to actual products.
  • Page 11 Parts Name Display For some model: For some model: temp. cooling power receiver indicator indicator indicator window heating indicator display cooling indicator receiver power heating temp. drying window indicator display indicator indicator indicator drying indicator For some model: display temp. indicator Power LED color indicator: Green-status-ON.
  • Page 12: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button MODE button FAN button TURBO button ▲/ button button button SLEEP button I FEEL button TIMER ON / TIMER OFF button CLOCK button QUIET button X-FAN button (Note: X-FAN is the same with BLOW.) LIGHT button button TEMP button...
  • Page 13: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: ● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 14 Introduction for buttons on remote controller Note: ● For preventing cold air, after starting up heating mode, indoor unit will delay 1~5 minutes to blow air (actual delay time is depend on indoor ambient temperature). ● Set temperature range from remote controller: 16~30℃ (61-86°F); Fan speed: auto, low speed, low-medium speed,medium speed, medium-high speed,high speed.
  • Page 15 Introduction for buttons on remote controller Note: ● Press this button continuously more than 2s, the main unit will swing back and forth from left to right, and then loosen the button, the unit will stop swinging and present position of guide louver will be kept immediately. ●...
  • Page 16 Introduction for buttons on remote controller main unit setting temperature will increase 1 , two hours, setting temperature increa- sed 2 , then the unit will run at this setting temperature; In Heat mode: sleep status after run for one hour, the setting temperature will decrease 1 , two hours, setting temperature will decrease 2 , then the unit will run at this setting temperature.
  • Page 17 Introduction for buttons on remote controller the remote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature. TIMER ON / TIMER OFF button ● TIMER ON button "TIMER ON" button can set the time for timer on. After pressing this button, " "...
  • Page 18 Introduction for buttons on remote controller QUIET button Press this button, the Quiet status is under the Auto Quiet mode (display " " and "AUTO" signal ) and Quiet mode (display " " singal) and Quiet OFF (there is no signal of "...
  • Page 19: Function Introduction For Combination Buttons

    Introduction for buttons on remote controller LCD displays " ". Press the button for the second time to start healthy and scavenging functions simultaneously; LCD displays " " and " " . Press this button for the third time to quit healthy and scavenging functions simultaneously. Press the button for the fourth time to start healthy function;...
  • Page 20 Function introduction for combination buttons ● Under energy-saving function, set temperature can’t be adjusted. Press "TURBO" button and the remote controller won’t send signal. ● Sleep function and energy-saving function can’t operate at the same time. If energy-saving function has been set under cooling mode, press sleep button will cancel energy-saving function.
  • Page 21 Function introduction for combination buttons Dry Contact function Interface of dry contact device is provided, while the dry contact device shall be prepared and installed by the customer. Multi timer function ● THREE TIMERS Press uninterruptedly “LIGHT” button 6 times in 7 seconds,thus we enter the “Multi Timer”...
  • Page 22: Operation Guide

    Function introduction for combination buttons Note: 1. Memory function does not cover the “Multi Timer”. 2. The time calibration of remote controller is not effective after setting “Multi Timer”. 3. “Multi Timer” function is prioritized over the original “TIMER ON”and “TIMER OFF” function.
  • Page 23: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
  • Page 24 Clean and maintenance Open panel Pull out the panel to a certain ● Use dust catcher or water to the water (below 45℃ ) to clean it, and then put it in a shady and cool place to dry. panel cover tightly. WARNING operation environment, clean frequency can be increased.
  • Page 25 Clean and Maintenance NOTICE: Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether air switch, plug and socket are in good condition. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
  • Page 26: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Check items Solution ● Whether it's interfered severely ● Pull out the plug. Reinsert (such as static electricity,stable the plug after about 3min, and voltage)?
  • Page 27 Malfunction analysis Phenomenon Check items Solution ● Power failure? ● Wait until power recovery. ● Is plug loose? ● Reinsert the plug. ● Air switch trips off or fuse is ● Ask professional to replace burnt out? air switch or fuse. Air condit- ●...
  • Page 28 Malfunction analysis Phenomenon Check items Solution ● Whether there’s odour source, ● Eliminate the odour source. Odours are such as furniture and cigarette, emitted ● Clean the filter. etc. ● Whether there’s interference, ● Disconnect power, put back Air conditioner such as thunder, wireless power, and then turn on the operates nor-...
  • Page 29 Malfunction analysis Error Code ● When air conditioner status is abnorm al, temperature indicator on indoor unit will ation of error code. Error code Troubleshooting It can be eliminated after restarting the unit. If not, please It can be eliminated after restarting the unit. If not, please It can be eliminated after restarting the unit.
  • Page 30: Installation Dimension Diagram

    Installation dimension diagram Space to the wall At least 15cm At least 15cm Space to the wall Drainage pipe...
  • Page 31: Safety Precautions For Installing And Relocating The Unit

    Safety precautions for installing and relocating the unit To ensure safety, please be mindful of the following precautions. Warning When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.
  • Page 32: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: ●...
  • Page 33: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. air switch. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
  • Page 34: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location rm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the plastic expansion particles in the holes. 3.
  • Page 35 Installation of indoor unit Indoor outdoor Note: ● Pay attention to dust prevention and take relevant safety measures when opening the hole. ● The plastic expansion particles are Φ55 5-10° not provided and should be bought locally. Step four: outlet pipe 1.
  • Page 36 Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench Φ 6 15~20 Φ 9.52 30~40 union nut Φ 12 45~55 pipe Φ 16 60~65 torque wrench Φ 19 70~75 indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.
  • Page 37 Installation of indoor unit 2. Make the power connection wire go through the cable-cross hole at the back cable-cross hole of indoor unit and then pull it out from the front side. power connection wire 3. Remove the wire clip; connect the power connection wire to the wiring terminal with wire clip.
  • Page 38 Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
  • Page 39: Installation Of Outdoor Unit

    Installation of outdoor unit (select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. Note: installing the outdoor unit. ●...
  • Page 40 Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw on the right han- 3. Pretightening the union nut with dle of outdoor unit and then remove hand. the handle. pipe joint union nut 2. Remove the screw cap of valve and 4.
  • Page 41 Installation of outdoor unit 2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit). Note: ● Never cut the power connection wire to prolong or shorten the distance. Step six: neaten the pipes 1.
  • Page 42: Vacuum Pumping

    Vacuum pumping Use vacuum pump piezometer 1. Remove the valve caps on the liquid valve and gas gas valve valve and the nut of refri- refrigerant charging valve cap gerant charging vent. vent 2. Connect the charging hose nut of refrigerant of piezometer to the refri- charging vent gerant charging vent of gas...
  • Page 43: Check After Installation

    Check after installation Items to be checked Possible malfunction The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? (heating) capacity. It may cause condensation and water dripping. It may cause condensation and water Is water drained well? dripping.
  • Page 44 Configuration of connection pipe 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe. Max length Max length Cooling Cooling of connec- of connec- capacity capacity tion pipe tion pipe 5000Btu/h 24000Btu/h...
  • Page 45 Configuration of connection pipe Additional refrigerant charging amount for R22, R407C, R410A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m) Φ6 Φ9.52 or Φ12 Φ6 or Φ9.52 Φ16 or Φ19 Φ12 Φ19 or Φ22.2 Φ16...
  • Page 46: Pipe Expanding Method

    Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port ● Confirm the pipe length according to ● Expand the port with expander. the distance of indoor unit and hard outdoor unit.
  • Page 48 Please record the following product information ● Model ● Serial No. ● Name of the franchiser ● Date of purchase The continuous improvement of products , such as function is changed, without prior notice, if there are any questions, please contact customer service ,Sorry for the inconvenience please forgiveness ToolBox Customer Service Centre:...

This manual is also suitable for:

Gim09acGim12aeGim12acGim18aeGim18ac

Table of Contents