OPERATOR SPECIFICATIONS
HP
Phase
1
Single
Three
1-1/2
Single
2
Three
Accessory Outlets are rated for 120 Vac, 6 Amps maximum. NOTE: The outlet is only available on models with 120 Vac input. The 120 Vac outlet is
automatically disabled when the operator is configured for any voltage other then 120 Vac.
For 240 Vac multiply length by 2
For 480 Vac multiply length by 4
For 575 Vac multiply length by 4.8
NOTE: Chart is based on 5% voltage drop
INTRODUCTION
Main AC Supply
Vac
120 Vac
208-240 Vac
208-240 Vac
480 Vac
575 Vac
120 Vac
208-240 Vac
208-240 Vac
480 Vac
575 Vac
10000
1000
100
10
1
2
Full Load Amps
16 Amps (22 Amps including Accessory Outlets)
20 Amps (26 Amps including Accessory Outlets)
120 VAC POWER WIRE LENGTH
3
4 5 6 7 8 9 10
Operator full load current (Amps)
7
8 Amps
6 Amps
3 Amps
1.8 Amps
10 Amps
8 Amps
4 Amps
3 Amps
20
30
40
100