Learn Button; Diagnostic Display; Handing Buttons; Bipart Delay - Chamberlain Elite SL595101U Series Installation Manual

Heavy duty industrial ac slide gate operator
Table of Contents

Advertisement

The LEARN button is used for programming (refer to Programming).
The diagnostic display will show the operator type, firmware version, and codes. The operator type will display as "SL" followed by a "59"
which indicates the operator type as SL595. The firmware version will show after the operator type, example "1.2". For more information
about the codes refer to the Troubleshooting section.
The handing buttons are used to determine which direction the gate will open and they are also used to set the limits
(refer to the Adjustment section).
OPEN RIGHT
If the operator is installed on the right side of the drive when looking out of the property, a swing gate
will swing to the right (turn counter clockwise) when opening and a slide gate will slide to the right when
opening.
OPEN LEFT
If the operator is mounted on the left side of the drive when looking out of the property, a swing gate will swing to the left (turn
clockwise) when opening and a slide gate will slide to the left when opening.
NOTE: For gates installed on the outside of the property, the setting will be opposite. Determine the direction by looking towards the property from the
outside.
Used in dual gate applications where a maglock, solenoid lock, or decorative overlay would require one gate to close before the other.
The BIPART DELAY is also used in applications where one gate travels a longer distance than the other.
ON/OFF
The operator with the BIPART DELAY dial ON will delay from the close limit when opening and be the first to close from
the open limit.
BOTH OFF
No affect.
BOTH ON
No affect.
The TTC is factory set to OFF (0). Rotate the TIMER-TO-CLOSE dial to the desired setting (0 to 180 seconds). Any radio command, single
button control, or CLOSE command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from
the open controls, loops, close edges, and close photoelectric sensors.
0 seconds (OFF)
The gate will remain open until the operator receives another command from a control.
1-180 seconds (ON)
The gate will automatically close after the specified time period.
CONTROL BOARD OVERVIEW

LEARN BUTTON

DIAGNOSTIC DISPLAY

HANDING BUTTONS

BIPART DELAY

TIMER-TO-CLOSE (TTC)