Fanmaster 3 Series Instruction Manual

Fanmaster 3 Series Instruction Manual

Industrial diesel fan heater (direct-fired)

Advertisement

Quick Links

FA NM A ST E R
cooling heating ventilation extraction
INSTRUCTION MANUAL
INDUSTRIAL DIESEL FAN HEATER (DIRECT-FIRED)
MODEL: IDH3-20, IDH3-30, IDH3-50
SERIES 3
FOR INDUSTRIAL USE ONLY
MUST BE USED IN WELL VENTILATED AREAS
TO PREVENT SERIOUS INJURY, READ & UNDERSTAND ALL WARNINGS &
INSTRUCTIONS BEFORE USE. PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS

Advertisement

Table of Contents
loading

Summary of Contents for Fanmaster 3 Series

  • Page 1 FA NM A ST E R cooling heating ventilation extraction INSTRUCTION MANUAL INDUSTRIAL DIESEL FAN HEATER (DIRECT-FIRED) MODEL: IDH3-20, IDH3-30, IDH3-50 SERIES 3 FOR INDUSTRIAL USE ONLY MUST BE USED IN WELL VENTILATED AREAS TO PREVENT SERIOUS INJURY, READ & UNDERSTAND ALL WARNINGS & INSTRUCTIONS BEFORE USE.
  • Page 2: For Your Information

    FOR YOUR INFORMATION Thank you for purchasing a Fanmaster diesel heater. Please read this instruction manual carefully before using this heater. Disclaimer: Fanmaster reserves the right to make alterations to specifications, quantities, dimensions, for production or other reasons, subsequent to publication.
  • Page 3 BENT, TAUT, STRETCHED, CRUSHED OR ANY WAY DAMAGED. • IF THE POWER CORD AND/OR PLUG IS DAMAGED, IT MUST BE REPLACED BY FANMASTER, A SERVICE AGENT OR A QUALIFIED PERSONS. • THE FRONT OUTLET IS VERY HOT DURING OPERATION. DO NOT TOUCH! BURN DANGER.
  • Page 4: Product Description And Specifications

    2. PRODUCT DESCRIPTION & SPECIFICATIONS PRODUCT DESCRIPTION Industrial diesel or kerosene direct fired portable space/fan heater with open combustion chamber, series 3. SPECIFICATIONS MODEL IDH3-20 IDH3-30 IDH3-50 20KW 30KW 50KW Heat Output* 68,240 BTU 102,360 BTU 170,600 BTU Air Flow (L/s) Fuel Type Diesel or Kerosene Diesel or Kerosene...
  • Page 5: Assembling Instructions

    3. ASSEMBLING INSTRUCTIONS Remove the heater from the carton. If the heater is damaged, please contact Fanmaster or where you purchased the heater from. The following parts are supplied in the carton: Fig 2. Pos. Description Handle Washer ø6 Clamping Screw...
  • Page 6 4. OPERATING INSTRUCTIONS • Position the heater on a flat, level, non-flammable & solid surface. • Direct-fired heaters are intended for use in outdoor open areas or in indoor well ventilated areas. For indoor use, provide permanent ventilation openings of at least 25 cm²/kW, equally distributed between floor and high level, with a minimum of 250 cm².
  • Page 7 If the heater is in lock-out mode, check and remove the cause of lock-out before restarting the heater. To reset, turn the ON/OFF switch to 0 and then again to I. If problem continues please contact Fanmaster. Turning the thermostat control knob will NOT reset the heater.
  • Page 8: Cleaning, Maintenance And Storage

    5. CLEANING, MAINTENANCE & STORAGE Please refer to the Maintenance Schedule & Logbook that came with this heater. • Before starting any maintenance task, shut down, unplug and let the heater cool down for at least 15 minutes. • Do not attempt any electrical repair yourself. If the heater needs service or repair, contact a qualified person.
  • Page 9 5. CLEANING, MAINTENANCE & STORAGE - CON Air Pump Pressure Adjustment (Fig 4.) The Air Pump pressure is factory set and must be checked and adjusted by qualified technicians only. Tampering with the unit may be dangerous. Remove pressure gauge cap. Connect a pressure gauge on the pressure measuring port on the rear guard.
  • Page 10: Wiring Diagram

    6. WIRING DIAGRAM IDH3-20 & IDH3-30 IDH3-50...
  • Page 11: Spare Parts

    7. SPARE PARTS PART NO. DESCRIPTION TO SUIT SP-IDH320-MK IDH3-20 Maintenance Kit - Fuel Nozzle, Fuel Filter & Fuel Line SP-IDH330-MK IDH3-30 Maintenance Kit - Fuel Nozzle, Fuel Filter & Fuel Line SP-IDH350-MK IDH3-50 Maintenance Kit - Fuel Nozzle, Fuel Filter & Fuel Line SP-IDH3-FN1 Fuel Nozzle IDH3-20...
  • Page 12: Troubleshooting

    8. TROUBLESHOOTING PROBLEM CAUSE SOLUTION Check power supply & voltage No power or low voltage Check fuse & replace if necessary Motor does not start Faulty or damaged power Check & replace cord E1 displayed on the Faulty motor/capacitor Check & if necessary replace screen Detect the cause of overheating.
  • Page 13 8. TROUBLESHOOTING - CONTINUED REASON PROCESS SOLUTION Remove the fuel cap & add enough fuel. Fuel Exhausted Check Fuel Using a mult-meter, check both ends of thermostat. If there is a resistance value showing the thermostat is working. If there is no resistance, replace thermostat.
  • Page 14 8. TROUBLESHOOTING - CONTINUED REASON PROCESS SOLUTION Open the control panel. Using a multi-meter check motor circuit. Motor not Check Motor working Condition Take out the air line. Carefully check the line surface. Replace if there are any cracks or damages.
  • Page 15 8. TROUBLESHOOTING - CONTINUED REASON PROCESS SOLUTION Connect a pressure gauge. While the heater is running block the air outlet & pressure adjusting point. If the pressure gauge needle reaches 14PSI the air pump is good. If it fails to reach this point, replace air pump.
  • Page 16: Warranty

    To make a claim under the warranty, take the product (with proof of purchase) to the store where you purchased the product or go to https://www.fanmaster.com.au/support. This warranty is given by Fanmaster Pty Ltd ABN: 45 353 934 457 Unit 1/6-8 Yalgar Rd, KIRRAWEE NSW 2232 P: 1300 900 345 E: support@fanmaster.com.au...
  • Page 17 8. TROUBLESHOOTING - CONTINUED...
  • Page 20 FA NM A ST E R cooling heating ventilation extraction Fanmaster Pty Ltd | 1/6-8 Yalgar Road, KIRRAWEE NSW 2232 1300 900 345 | sales@fanmaster.com.au | www.fanmaster.com.au N11664 MADE IN CHINA...