INDUSTRIAL DIESEL FAN HEATER (DIRECT-FIRED)
MODEL: IDH2-20, IDH2-30, IDH2-50
FOR INDUSTRIAL USE ONLY
ADEQUATE VENTILATION REQUIRED
TO PREVENT SERIOUS INJURY, READ & UNDERSTAND ALL WARNINGS &
INSTRUCTIONS BEFORE USE. PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS

Advertisement

Table of Contents
loading

Summary of Contents for Fanmaster IDH2-20

  • Page 1 FA NM A ST E R cooling heating ventilation extraction INSTRUCTION MANUAL INDUSTRIAL DIESEL FAN HEATER (DIRECT-FIRED) MODEL: IDH2-20, IDH2-30, IDH2-50 FOR INDUSTRIAL USE ONLY ADEQUATE VENTILATION REQUIRED TO PREVENT SERIOUS INJURY, READ & UNDERSTAND ALL WARNINGS & INSTRUCTIONS BEFORE USE. PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS...
  • Page 2: For Your Information

    FOR YOUR INFORMATION Thank you for purchasing a Fanmaster diesel heater. Please read this instruction manual carefully before using this heater. Disclaimer: Fanmaster reserves the right to make alterations to specifications, quantities, dimensions, for production or other reasons, subsequent to publication.
  • Page 3 ALWAYS CHECK THE POWER CABLE BEFORE USING THE APPLIANCE. IT MUST NOT BE BENT, TAUT, STRETCHED, CRUSHED OR ANY WAY DAMAGED. • IF THE POWER CORD AND/OR PLUG IS DAMAGED, IT MUST BE REPLACED BY FANMASTER, A SERVICE AGENT OR A QUALIFIED PERSONS. •...
  • Page 4: Product Description And Specifications

    2. PRODUCT DESCRIPTION & SPECIFICATIONS PRODUCT DESCRIPTION Industrial diesel or kerosene direct fired portable space/fan heater with open combustion chamber. SPECIFICATIONS MODEL IDH2-20 IDH2-30 IDH2-50 20KW 30KW 50KW Heat Output* 68,240 BTU 102,360 BTU 170,600 BTU Air Flow (L/s) Fuel Type...
  • Page 5: Assembling Instructions

    3. ASSEMBLING INSTRUCTIONS Remove the heater from the carton. If the heater is damaged, please contact Fanmaster or where you purchased the heater from. IDH2-20: This heater only requires to install the plastic handle (see Fig 1.) Pos. Description Screw...
  • Page 6 Direct-fired heaters are intended for use in outdoor open areas or in indoor well ventilated areas. For indoor use, provide permanent ventilation openings of at least 25 cm²/kW, equally distributed between floor and high level, with a minimum of 250 cm². IDH2-20 IDH2-30 IDH2-50 Minimum Opening Size...
  • Page 7 The fuel gauge on top of the tank allows you to check the fuel level • Connect the plug to the relevant power source IDH2-20 & IDH2-30 • The power indicator will light up & the ambient temperature will display.
  • Page 8 If the heater is in lock-out mode, check and remove the cause of lock-out before restarting the heater. To reset, turn the ON/OFF switch to 0 and then again to I. If problem continues please contact Fanmaster. Turning the thermostat control knob will NOT reset the heater.
  • Page 9: Cleaning, Maintenance And Storage

    5. CLEANING, MAINTENANCE & STORAGE Please refer to the Maintenance Schedule & Logbook that came with this heater. • Before starting any maintenance task, shut down, unplug and let the heater cool down for at least 15 minutes. • Do not attempt any electrical repair yourself. If the heater needs service or repair, contact a qualified person.
  • Page 10 Start heater and read air pressure value. If necessary adjust pressure to the correct value turning the adjusting screw (the air vent hole in the adjusting screw middle) clockwise to increase, anticlockwise to decrease the pressure: Model Air Pressure (bar) IDH2-20 0.32 IDH2-30 0.31 IDH2-50 0.38 Fig 4.
  • Page 11: Wiring Diagram

    6. WIRING DIAGRAM WIRING DIAGRAM: IDH2-20 & IDH2-30 WIRING DIAGRAM: IDH2-50...
  • Page 12: Parts Breakdown

    7. PARTS BREAKDOWN IDH2-20...
  • Page 13 7. PARTS BREAKDOWN - CONTINUED IDH2-30...
  • Page 14 7. PARTS BREAKOWN - CONTINUED IDH2-50...
  • Page 15: Troubleshooting

    8. TROUBLESHOOTING PROBLEM CAUSE SOLUTION Check power supply & voltage No power or low voltage Check fuse & replace if necessary Motor does not start Faulty or damaged power Check & replace cord E1 displayed on the Faulty motor/capacitor Check & if necessary replace screen Detect the cause of overheating.
  • Page 16: Warranty

    8. TROUBLESHOOTING - CONTINUED 8. WARRANTY REASON PROCESS SOLUTION Remove the fuel cap & add enough fuel. Fuel Exhausted Check Fuel Using a mult-meter, check both ends of thermostat. If there is a resistance value showing the thermostat is working. If there is no resistance, replace thermostat.
  • Page 17 8. TROUBLESHOOTING - CONTINUED REASON PROCESS SOLUTION Open the control panel. Using a multi-meter check motor circuit. Motor not Check Motor working Condition Take out the air line. Carefully check the line surface. Replace if there are any cracks or damages.
  • Page 18 8. TROUBLESHOOTING - CONTINUED REASON PROCESS SOLUTION Connect a pressure gauge. While the heater is running block the air outlet & pressure adjusting point. If the pressure gauge needle reaches 14PSI the air pump is good. If it fails to reach this point, replace air pump.
  • Page 19 To make a claim under the warranty, take the product (with proof of purchase) to the store where you purchased the product or go to https://www.fanmaster.com.au/warranty-claims-returns. This warranty is given by Fanmaster Pty Ltd ABN: 45 353 934 457 Unit 1/6-8 Yalgar Rd, KIRRAWEE NSW 2232 P: 1300 900 345 E: warranties@fanmaster.com.au...
  • Page 20 FA NM A ST E R cooling heating ventilation extraction Fanmaster Pty Ltd | 1/6-8 Yalgar Road, KIRRAWEE NSW 2232 1300 900 345 | sales@fanmaster.com.au | www.fanmaster.com.au N11664 MADE IN CHINA...