ELECTRICAL CONNECTIONS (CONT.)
4
3-WIRE POWER CORD INSTALLATION
WARNING: The neutral or ground wire of
the power cord must be connected to
the neutral terminal located in the cen-
ter of the terminal block. The power
leads must be connected to the left
and the right terminals of the terminal
block.
A
Remove the 3 lower terminal screws from the termi-
nal block. Insert the 3 power cord terminal rings
into each one of the terminals of the terminal
block. Be certain that the center wire (white/neu-
tral) is connected to the center of the terminal
block. Tighten nuts securely into the terminal block.
DO NOT remove the ground strap connection.
Ground
plate
Power
cord
B
Skip to Step 8 and proceed with the installation.
36
Installation Instructions
Terminal block
(appearance
may vary)
Neutral
terminal
Ground
strap
5
4-WIRE POWER CORD INSTALLATION
WARNING: The neutral wire of the supply
circuit must be connected to the neu-
tral terminal located in the center of the
terminal block. The power leads must
be connected to the left and the right
terminals of the terminal block. The 4th
grounding lead must be connected to
the frame of the range with the ground
plate and the ground screw.
A
Remove the 3 lower terminal nuts from the terminal
block. Remove the ground screw and ground
plate and retain them.
B
Cut and discard the ground strap. DO NOT DIS-
CARD ANY SCREWS.
C
Insert the one ground screw into the power cord
ground wire terminal ring, through the ground plate
and into the frame of the range.
D
Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and into
the lower terminals of the terminal block. Be certain
that the center wire (white/neutral) is connected to
the center lower position of the terminal block.
Tighten screws securely into the terminal block.
Before
Terminal
block
Ground strap
After
Terminal
block
Ground
screw
E
Skip to Step 8 and proceed with the installation.
Ground strap
or
Neutral
terminal
Neutral terminal
Ground
plate
(grounding
to range)