Replacing the Lamp
When the "Lamp Replacement" warning appears on screen it is time to replace the lamp. (Lamp LED warming
light will appear red).
"
"
Press OK to make the warning disappear
After replacing the lamp please reset the lamp timer.
Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use
the same lamp this may cause the lamp to explode.
To Reset Lamp Timer please follow these steps:
1.) Press "MENU" and "VOL ADJ
the RPTV is on.
2.) "Lamp Timer Reset" should appear on screen.
3.) Press "OK" to reset the lamp timer.

Status LEDs

There are two status LEDs on the front of the RPTV.
State
AC off
Standby mode
Warm-up
Operation mode
Cool down mode
Lamp caution
ERROR MESSAGE
Error Code
21
32
52
.
" buttons on the right hand side of the RPTV for three (3) seconds while
POWER LED
Not lit
Red
Green
Green
Red
Green
POWER LED
Flashes green twice,
times then Red once.
Flashes green three
times, then Red twice.
Flashes green five
times, then Red twice.
READY LED
Not lit
AC power is not connected
Not lit
AC power is connected and the RPTV is
in standby mode.
Flashing
AC power is connected and the power
Red
button has just been turned on.
Not lit
AC power is connected, the power button
has been pressed and the lamp has been
warmed up.
Flashing
AC power is connected and the power
Red
button has just been turned off.
Red
Lamp life has been ended. Please Replace
the lamp.
READY LED
Not lit
One of the cooling fans has failed.
Flashing
Indicates lamp trouble or failure. The
Red
RPTV will automatically shut down and
restart itself.
Indicates hardware error. Power off the
Not lit
RPTV, wait one minute, and then restart
the RPTV.