Status LEDs

There are two status LEDs on the front of your Micro Chip Display Projection TV.

Normal Operation

State
Power LED Lamp LED
AC off
Not lit
Standby mode
Orange
Warm-up
Blue
Cool down
Orange
Operation mode Blue

Error Codes

Error
Power LED
Code
Flashes blue twice,
21
then orange once.
Flashes blue three
32
times, then orange
twice.
Flashes blue five
52
times, then orange
twice.
Description
Not lit
AC power not connected
Not lit
AC power is connected and
your RPTV is in standby
mode.
Orange Flashing AC power is connected and
the power button has just been
turned on.
Orange Flashing Powering off.
Not lit
AC power is connected, the
power button has been
pressed, and the lamp has
warmed up.
Lamp LED
One of the cooling fans has failed.
Not lit
See "Support" on page 49.
Lamp trouble or failure. Your RPTV
automatically shut down and
Flashing
restart itself. If this does not solve
the problem, see "Support" on
page 49.
Hardware error. Shut off your
RPTV, wait one minute, then
Not lit
restart your RPTV. If this does not
solve the problem, see "Support"
on page 49.