Led Status - Vivitek DVR5612 User Manual

56" micro chip display projection tv projector user guide
Table of Contents

Advertisement

Power LED
Normal Operation
States
Power LED
AC off
Not lit
Standby mode
Orange
Warm-up/Cool down
Blue
Operation mode
Blue
Error Codes
States
Power LED
21
Flashes blue twice,
then orange once
32
Flashes blue three
times, then orange
twice.
52
Flashes blue five
times, then orange
twice.
There are two status LEDs on the front of your Micro Chip
Display Projection RP TV.
You may obtain the display's related status through the LED
in the front panel. Their meanings are explained as follows:
Lamp LED
Lamp LED
Not lit
Not lit
Flashing
Not lit
Lamp LED
Not lit
Flashing
Flashing
Status Description
AC power not connected
AC power is connected and your RPTV is in
standby mode.
AC power is connected and the power button has
just been turned on or off.
AC power is connected, the power button has
been pressed, and the lamp has warmed up
Status Description
One of the cooling fans has failed. Call Service
Center to help you solve the question.
Lamp trouble or failure. Your RPTV automatically
shut down and restart itself. If this does not solve
the problem, Call Service Center to help you solve
the question.
Hardware error. Shut off your RPTV, wait one
minute, then restart your RPTV. If this does not
solve the problem,Call Service Center to help you
solve the question.
13