unit
string[32]
commonname
string[64]
validdays
0 ~ 9999

Drive the Digital Output

Note: This request requires Viewer privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0 or 1; "0" means inactive or normal state, while "1" means active or triggered state.
PARAMETER
VALUE
do<num>
0, 1
return
<return page>
Example: Drive the digital output 1 to triggered state and redirect to an empty page.
http://myserver/cgi-bin/dido/setdo.cgi?do1=1

Query Status of the Digital Input

Note: This request requires Viewer privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
If no parameter is specified, all of the digital input statuses will be returned.
VIVOTEK - A Leading Provider of Multimedia Communication Solutions
6/6
Organizational unit name in the certificate
information.
6/6
Common name in the certificate information.
6/6
Valid period for the certification.
DESCRIPTION
0 – Inactive, normal state
1 – Active, triggered state
Redirect to the page <return page> after the parameter is
assigned. The <return page> can be a full URL path or relative
path according to the current path. If you omit this parameter, it
will redirect to an empty page.