Clear Data Mode Serial Port Driver; Restore Factory Default Settings; Restart System - Vivotek VisualServer VS3102 User Manual

Networked video server
Hide thumbs Also See for VisualServer VS3102:
Table of Contents

Advertisement

Clear data mode serial port driver

This URL applies to the attached serial port device including supported PTZ cameras or non-supported
custom cameras. Note the serial port settings of custom cameras must be correctly defined in advance.
Send command to device attached to COM
/cgi-bin/senddata.cgi?data=123456,ABCDEF&flush=yes&wait=1000&read=6
This hyperlink will inform VisualServer to send out binary format commands to the COM with "0x12,
0x34, 0x56" followed by "0xAB, 0xCD, 0xEF". Each comma separates the commands by 200
milliseconds. "flush=yes" means the receive data buffer of COM port must be cleared before read. Then
read 6 bytes after waiting for 1000 milliseconds. The read data can be up to 128 bytes and will return as
ASCII coded hexadecimal value, e.g., 0x41, 0x42, 0x43 read from COM port will show in returned
homepage as 414243 instead of ABC.

Restore factory default settings

/setup/restore.cgi
VisualServer will automatically restart after restoring factory default configurations.

Restart system

/setup/reset.cgi
Restart VisualServer without warning.