2. MAINTENANCE & TROUBLESHOOTING

2.4 Error Status

When error is detected, all LEDs go off and
then the STATUS LED blinks or goes off
depending on error type as shown in the
table below.
LED status
Meaning
STATUS LED
Magnetic
blinks slowly.
deviation error
STATUS LED
EEPROM error
blinks quickly.
STATUS LED
Other than the
goes off.
above.
2.5

Clearing the Memory

The memory can be cleared to start afresh
with default settings.
1. Disconnect the power cable from the
equipment.
2. Reattach the cable while pressing the
[AUTO] and [ADJ] keys together.
After the memory has been cleared, the
sensor returns to the normal mode.
If the memory could not be cleared, the
STATUS LED blinks quickly.