Technibel KPAVM93R5TAA Technical Data & Service Manual page 41

Table of Contents

Advertisement

(6) Procedures When a Specific Component Does Not Work
1) Indoor fan does not operate.
Is fan motor capacitor
normal ?
Is there voltage output
of P .C.B. Ass'y for fan
motor ?
- Check resistance of
fan motor winding.
Replace the fan motor.
2) Flaps in indoor unit's air outlet does not operate, when you press SWEEP button.
Check the louver motor resistance.
Is auto louver motor normal?
Is 15P connector socket (RED)
attached to panel
connected firmly with 15P plug ?
Replace P .C.B. Ass'y in the
indoor unit.
3) Flap does not operate, when you press FAN AIM button. (When you press SWEEP button, flap operates.)
Does limit switch actuate?
I
15P
S
CONNECTOR SOCKET
attached to panel
connected firmly with 15P plug ?
Replace P .C.B. Ass'y in the
indoor unit.
N
O
Yes
No
Yes
Out
No
Yes
No
Yes
No
Yes
(RED)
No
Yes
41
Replace the capacitor.
Replace the P .C.B. Ass'y
in the indoor unit.
Replace the motor.
Connect firmly.
Replace the switch.
Connect firmly.
0650_M_S
0651_M_S
0652_M_S

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kpavm123r5taaKpavm183r5taa387105942387105943387105944

Table of Contents