Robot Coupe HI Series Instruction Manual page 12

Table of Contents

Advertisement

GEAR OIL METER
NOTE: Oil Meter Indicator is only available for
SPB-80HA and
SPB-80A.
Use the gear oil to lubricate the mixer and to prolong the life of
the mixer. Before using the mixer, please check the gear oil meter.
When the indicator of gear oil meter is above the half of the red circle,
the gear oil is full. Please re fill the gear oil when the indicator is
below the red circle.
GEAR OIL RENEWAL
CAUTION:
Please use Mobil lubricant "UBE HD 85W-140" to refill the gearbox of model
SPA-80A, SPB-80HA and
Please unscrew and leak the oil from the indicated oil-leaking hole. After finishing the leaking, re-screw
back tightly with the anti-leaking coat on the screw. Fill the gear oil to the indicated re-fill oil hole. We
recommended that this servicing or maintenance work must be carried out by trained technicians from a
Robot Coupe appointed distributor.
GEARBOX LUBRICANT
In terms of the rest model from SP100-S to SP60-S, please refill the lubricant inside the gearbox every 5
years. We recommended that this servicing or maintenance work must be carried out by trained technicians
from a Robot Coupe appointed distributor.
CAUTION:
Please use either Mobil lubricant "XHP 222" or Brugarolas "GRASA AGUILA PLEX 2-BOLSA" to
refill the gearbox of model SP100-S, SP25-S, SP30-S, SP40-S and SP60-S.
PLANETARY UNIT LUBRICANT
Please add only 2 pumps of grease to the planetary grease fitting once a year. In case there is a strange
noise coming from the planetary unit, please reapply grease to the planetary unit by using the grease gun.
We recommended that this servicing or maintenance work must be carried out by trained technicians from a
Robot Coupe appointed distributor.
CAUTION:
Please use TACBECON grease "GL-210" to lubricate the planetary unit.
Maintenance
SPB-80A.
SPA-80HA, SPA-80A,
11
SPA-80HA,

Advertisement

Table of Contents
loading

Table of Contents