Valve Tray Replacement - Regency Fireplace Products Greenfire GF1500L Owners & Installation Manual

Table of Contents

Advertisement

maintenance

Valve Tray Replacement

PRIOR TO VALVE TRAY REPLACEMENT, ENSURE UNIT
HAS COOLED TO ROOM TEMPERATURE, ALL POWER IS
DISCONNECTED AND GAS SUPPLY IT TURNED OFF.
1. Remove faceplate, inner frame, glass door, front trim piece and inner
panels - see instructions in this manual.
2. Remove logs.
3. Remove burner side panels by lifting out as shown in Diagram 1.
Diagram 1 - Burner Side Panels
4. Remove burner by removing 2 screws in locations shown below.
Diagram 2 - Burner Screw Locations
60
|
Greenfire® GF1500L-2 Gas Fireplace
5. Remove rear log tray by removing 3 screws as shown in Diagram 3 below.
Diagram 3 - Log Tray screws
6. Remove burner by removing 16 screws in locations shown
below.
Diagram 4 - Valve Tray Screw Locations
7. Lift out valve tray.
Diagram 5 - Valve Tray Removal
8. Replace valve tray and reverse steps.